Allen Bradley ControlLogix 1756-OA16I

Product image is representative; revision or series may vary. Contact us to request a specific version.

1756-OA16I

|

The Allen-Bradley 1756-OA16I is a 1756 ControlLogix Discrete AC output module. This module features Sixteen (16) individually isolated AC output channels in each channel. It delivers 120 VAC / 240 VAC nominal voltage output within voltage range of 74-265 VAC, 47-63 Hz. It has continuous output current per point of 2 A @ 30 °C (86 °F) linear derating and 1 A @ 60 °C (140 °F) linear derating.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Technical specifications for 1756-OA16I

ManufacturerAllen Bradley
CategoryPLCs
Product LineControlLogix
Part Number1756-OA16I
UPC612598164516
Weight0.63 lbs (0.28 kg)
Operating Voltage Range74-265 VAC
Module TypeDigital AC Output Module
Series1756 ControlLogix
No. of OutputsSixteen (16) isolated outputs
Output Voltage120/240 VAC output
Output Delay Time, OFF to ON9.3 ms @ 60 Hz; 11 ms @ 50 Hz
OFF state leakage current3 mA per point
Backplane Current at 5.1 Volts225 mA
Continuous current per point2 A @ 30 °C (86 °F) linear derating; 1 A @ 60 °C (140 °F) linear derating
Continuous current per module, max5 A @ 30 °C (86 °F) linear derating; 4 A @ 60 °C (140 °F) linear derating
Outputs16 Points Individually Isolated
Voltage120-240 Volts AC
Maximum Output Current Rating-Point2 Amps at 30 degrees Celsius, 1 Amp at 60 degrees Celsius
Maximum Output Current Rating-Module5 Amps at 30 degrees Celsius, 4 Amps at 60 degrees Celsius
Power Dissipation (Max)5.5 Watts at 60 degrees Celsius
Backplane Current at 5 Volts300 milliamps
Backplane Current at 24 Volts3 milliamps
Removeable Terminal Block(s)1756-TBCH, 1756-TBS6H
Isolation Voltage50 Volts Continuous
EnclosureNone

The Allen-Bradley 1756-OA16I is a Sixteen (16) channel discrete output module from the ControlLogix product family. This module delivers an output voltage range of 75-265VAC with frequency of 47-63 Hz while the nominal voltage output is 120 / 240VAC and frequency of 50/60 Hz.

The Allen-Bradley 1756-OA16I requires use of Removable Terminal Block (RTB) to provide wiring connections to the electrical loads connected to each of the module’s output channels. Compatible terminal blocks are 1756-TBCH and 1756-TBS6H. Each channel of this module has an output delay time of 9.3 ms @ 60 Hz and 11 ms @ 50 Hz, both for Off to On transition and 9.3 ms @ 60 Hz and 11 ms @ 50 Hz for On to Off transition. This moduel has a current draw of 300 mA at 5.1 VDC and 2.5 mA at 24VDC while the total backplane power requirement 1.59 Watts.

The 1756-OA16I is a single slot module that is mounted to any 1756 chassis. Compatible chassis are 1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17. This module may also be installed in the local rack, along the ControlLogix controllers or to a remote I/O rack with a 1756 Communication adapter.

The 1756-OA16I supports configuration of fault mode per point. Configurable states are Hold last state, On or Off where Off is default. It also permits configuration of output state during program mode with configurable settings are Hold last state, On or Off where Off is default. This module is not provided with internal fusing however, isolation voltage is present to this module with rating of 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output.

Its operational voltage ranges between 74 and 265V AC at 47-63 Hz, and exhibits an output signal delay time of 9.3 ms at 60Hz and one of 11ms at 50Hz for both ON to OFF and OFF to ON. The 1756-OA16I has a backplane current draw of 300mA at 5.1V and 2.5A at 24V and an aggregate backplane power of 1.59W. It has a thermal dissipation of 18.76 BTU/hr and dissipates 5.5W at 60 °C (140 °F). The 1756-OA16I has a leakage current of 3mA per point and in the ON state, it has a peak drop voltage of 1.5V at 2A and 6V at a load current of <50mA. The maximum current on each output point is 2A at 30 °C and 1A at 60 °C and the aggregate current on the output module is 5A at 30 °C and 4A at 60 °C. The 1756-OA16I has an inrush current of 20A for 43ms per output point, repeatable every 2 s at 60 °C, and the lowest current load sustain on each point is 10mA. It has an output signal schedule time of 16.7s, and has an isolation voltage of 250V, using basic insulation tested at 1350V AC for 2s between outputs-to-backplane and output-to-output. It has a single width slot and its RTB keying is user-defined. The 1756-OA16I has an open-style enclosure and is designated the T4A temperature code. Its operational temperature ranges between 0 and 60 °C at 5-95% non-condensing humidity and it has a maximum operational shock of 30G.

Revision Part #Also known as
1756-OA16I Ser A1756-OA16I/A, Series A, Rev A
Don't see your particular revision? Contact us now.