The Allen-Bradley 1756-OA16I is a 1756 ControlLogix Discrete AC output module. This module features Sixteen (16) individually isolated AC output channels in each channel. It delivers 120 VAC / 240 VAC nominal voltage output within voltage range of 74-265 VAC, 47-63 Hz. It has continuous output current per point of 2 A @ 30 °C (86 °F) linear derating and 1 A @ 60 °C (140 °F) linear derating.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Category | PLCs |
| Product Line | ControlLogix |
| Part Number | 1756-OA16I |
| UPC | 612598164516 |
| Weight | 0.63 lbs (0.28 kg) |
| Operating Voltage Range | 74-265 VAC |
| Module Type | Digital AC Output Module |
| Series | 1756 ControlLogix |
| No. of Outputs | Sixteen (16) isolated outputs |
| Output Voltage | 120/240 VAC output |
| Output Delay Time, OFF to ON | 9.3 ms @ 60 Hz; 11 ms @ 50 Hz |
| OFF state leakage current | 3 mA per point |
| Backplane Current at 5.1 Volts | 225 mA |
| Continuous current per point | 2 A @ 30 °C (86 °F) linear derating; 1 A @ 60 °C (140 °F) linear derating |
| Continuous current per module, max | 5 A @ 30 °C (86 °F) linear derating; 4 A @ 60 °C (140 °F) linear derating |
| Outputs | 16 Points Individually Isolated |
| Voltage | 120-240 Volts AC |
| Maximum Output Current Rating-Point | 2 Amps at 30 degrees Celsius, 1 Amp at 60 degrees Celsius |
| Maximum Output Current Rating-Module | 5 Amps at 30 degrees Celsius, 4 Amps at 60 degrees Celsius |
| Power Dissipation (Max) | 5.5 Watts at 60 degrees Celsius |
| Backplane Current at 5 Volts | 300 milliamps |
| Backplane Current at 24 Volts | 3 milliamps |
| Removeable Terminal Block(s) | 1756-TBCH, 1756-TBS6H |
| Isolation Voltage | 50 Volts Continuous |
| Enclosure | None |
The Allen-Bradley 1756-OA16I is a Sixteen (16) channel discrete output module from the ControlLogix product family. This module delivers an output voltage range of 75-265VAC with frequency of 47-63 Hz while the nominal voltage output is 120 / 240VAC and frequency of 50/60 Hz.
The Allen-Bradley 1756-OA16I requires use of Removable Terminal Block (RTB) to provide wiring connections to the electrical loads connected to each of the module’s output channels. Compatible terminal blocks are 1756-TBCH and 1756-TBS6H. Each channel of this module has an output delay time of 9.3 ms @ 60 Hz and 11 ms @ 50 Hz, both for Off to On transition and 9.3 ms @ 60 Hz and 11 ms @ 50 Hz for On to Off transition. This moduel has a current draw of 300 mA at 5.1 VDC and 2.5 mA at 24VDC while the total backplane power requirement 1.59 Watts.
The 1756-OA16I is a single slot module that is mounted to any 1756 chassis. Compatible chassis are 1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17. This module may also be installed in the local rack, along the ControlLogix controllers or to a remote I/O rack with a 1756 Communication adapter.
The 1756-OA16I supports configuration of fault mode per point. Configurable states are Hold last state, On or Off where Off is default. It also permits configuration of output state during program mode with configurable settings are Hold last state, On or Off where Off is default. This module is not provided with internal fusing however, isolation voltage is present to this module with rating of 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output.
Its operational voltage ranges between 74 and 265V AC at 47-63 Hz, and exhibits an output signal delay time of 9.3 ms at 60Hz and one of 11ms at 50Hz for both ON to OFF and OFF to ON. The 1756-OA16I has a backplane current draw of 300mA at 5.1V and 2.5A at 24V and an aggregate backplane power of 1.59W. It has a thermal dissipation of 18.76 BTU/hr and dissipates 5.5W at 60 °C (140 °F). The 1756-OA16I has a leakage current of 3mA per point and in the ON state, it has a peak drop voltage of 1.5V at 2A and 6V at a load current of <50mA. The maximum current on each output point is 2A at 30 °C and 1A at 60 °C and the aggregate current on the output module is 5A at 30 °C and 4A at 60 °C. The 1756-OA16I has an inrush current of 20A for 43ms per output point, repeatable every 2 s at 60 °C, and the lowest current load sustain on each point is 10mA. It has an output signal schedule time of 16.7s, and has an isolation voltage of 250V, using basic insulation tested at 1350V AC for 2s between outputs-to-backplane and output-to-output. It has a single width slot and its RTB keying is user-defined. The 1756-OA16I has an open-style enclosure and is designated the T4A temperature code. Its operational temperature ranges between 0 and 60 °C at 5-95% non-condensing humidity and it has a maximum operational shock of 30G.
| Revision Part # | Also known as | |
|---|---|---|
| 1756-OA16I Ser A | 1756-OA16I/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||
Yes, the 1756-OA16I includes a free 2-year DO Supply warranty. You can upgrade to a 3-year warranty at checkout for even more protection.
The 1756-OA16I delivers an output voltage range of 74-265VAC.
The 1756-OA16I uses the 1756-TBCH or 1756-TBS6H.
The module’s minimum load current is 10 mA per point.