The ProSoft MVI56-MBP Modbus Plus Dual Port Network Interface Module has 1 Slot(s) and Ladder Logic Data Transfer. The module has a Local or Remote Rack Type and a 57600 Baud.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Modbus Plus Dual Port Network Interface Module |
| Product Line | ControlLogix |
| Part Number | MVI56-MBP |
| Weight | 0.63 lbs (0.28 kg) |
| Slot(s) | 1 |
| Rack Type | Local or Remote |
| Data Transfer Type | Ladder Logic |
| Baud | 57,600 |
| Max. Word Reads and Writes | 100 |
| Master Command Count | 0 to 200 Commands |
| Module Data Transfer | 0 to 4000 Words |
| Backplane Current Load | 800 mA at 5 Volts DC |
The Prosoft MVI56-MBP is a Modbus Plus Communication Module. The module is a support device to Allen-Bradley’s ControlLogix PLCs. It helps in interfacing these processors with other devices that use Modbus Plus protocol. The MVI56-MBP supports both master and slave devices, enabling easy connection to Modicon processors and many other Modbus devices. It acts as a gateway between the ControlLogix backplane and the Modbus Plus network. The device has memory with 4000 words register, with the main function to exchange data between the PLC and the Modbus Plus network in an asynchronous way. Additionally, the MVI56-MBP can be configured as a slave to PLCs that must read or write data from the module’s memory. It is generally used to connect two brands of industrial networks, for example, the connection of Allen-Bradley PLCs to Modicon PLCs, and the linking of relays, drives, power monitor equipment, and similar Modbus Plus speaking devices to the ControlLogix backplanes.
The MVI56-MBP Modbus Plus Communication Module has a rechargeable Lithium Vanadium battery that is able to backup data inside of this module for 21 days. It backups CMOS and the real-time clock. The battery should be charged for twenty hours when the module is installed. It is engineered to last for the life of the module. If the device is more than 21 days without power supply, the module will return to the default BIOS settings.