Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen-Bradley 100-D110EN00 contactor is a Bulletin 100-D 3-pole contactor. It has a 110 Amps current rating. The electronic coil on the 100-D110EN00 is rated for 110 to 120 Volts DC voltage.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Contactor |
| Product Line | IEC 100 Contactors |
| Part Number | 100-D110EN00 |
| Weight | 3.00 lbs (1.36 kg) |
| Coil Type | Electronic |
| Current Rating | 110 Amps |
| Control Voltage | 110 to 120 Volts DC |
| Mounting | Panel |
| Poles | 3 |
| Maximum Altitude | 2000 meters |
| Working Temperature | -25 to 60 degrees Celsius |
| Protection Class | IP00 |
| Maximum Circuit Breaker Size | 150 Amps |
The Allen-Bradley 100-D110EN00 contactor is a 3-pole contactor from the Bulletin 100-D series. As a Bulletin 100-D series contactor, it can only be panel mounted. The 100-D contactors support AC or DC coil control. They also support either conventional or electronic coils. A 100-D series contactor with an electronic coil like the 100-D110EN00 contactor comes with an integrated PLC interface. The 100-D contactors support 115 to 860 Amps current ratings. Accessories for 100-D contactors like the 100-D110EN00 contactor include surge suppressors, IP20-rated terminal blocks, terminal covers, and terminal shields. The 100-D contactors are approved and certified by UL CSA, IEC, and CE standards. The 100-D110EN00 contactor is a 3-pole contactor with a current rating of 110 Amps. The contactor’s electronic coil is rated for 110 to 120 Volts DC. It is suitable for use on a circuit capable of delivering a maximum of 10,000 Volts rms.
The recommended maximum fuse size for the Allen-Bradley Bulletin 100-D series 100-D110EN00 contactor is 250 Amps and the recommended maximum circuit breaker size is 150 Amps. Allen-Bradley recommends use of 75 degrees Celsius-rated copper wire for the terminations on the contactor. The maximum voltage rating of the 100-D110EN00 contactor is 600 Volts AC. The impulse voltage rating for the contactor is 12 kilovolts. At 3-phase AC voltage, the output power ratings supported by the 100-D110EN00 contactor are 34 kilowatts at 230 Volts, 61 kilowatts at 400 Volts, and 106 kilowatts at 690 Volts. For single-phase AC voltage, the power ratings for the contactor are 10 Horsepower at 115 Volts and 25 Horsepower at 230 Volts. The storage temperature range is -40 to 80 degrees Celsius. The working temperature range is -25 to 60 degrees Celsius. The maximum recommended operating altitude is 2000 meters above sea level.