Description: This Micro 800 Programmable Logic Controller's specifications include 4-ch V/I Analog Input Unipolar 0-10V and is (non-isolated).
Available Now
Request a quote for 2080-IF4

Description: This Micro 800 Programmable Logic Controller's specifications include 4-ch V/I Analog Input Unipolar 0-10V and is (non-isolated).

top legal disclaimer
disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2080-IF4.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.4 with 6 reviews

    Technical Specifications for 2080-IF4

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2080-IF4
Product TypeAnalog Plug-in Module
Module TypeAnalog
Number of Single-Ended Inputs4
Analog Normal Operating Voltage Range0-10V DC
Analog Normal Operating Current Range0-20mA
Data Range0-65535
Repeatability+/- 0.1%
Input Channel ConfigurationThrough Configuration Software or the User Program
Update Time180ms per Enabled Channel
Input Group to Bus Isolation/Channel to Channel IsolationNon-Isolation
Operating Altitude 2000m
Max. Cable Length10m
UPC10885630058396
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2080-IF4
Product TypeAnalog Plug-in Module
Module TypeAnalog
Number of Single-Ended Inputs4
Analog Normal Operating Voltage Range0-10V DC
Analog Normal Operating Current Range0-20mA
Data Range0-65535
Repeatability+/- 0.1%
Input Channel ConfigurationThrough Configuration Software or the User Program
Update Time180ms per Enabled Channel
Input Group to Bus Isolation/Channel to Channel IsolationNon-Isolation
Operating Altitude 2000m
Max. Cable Length10m
UPC10885630058396
s

About 2080-IF4

The Allen Bradley Micro800 2080-IF4 module is a 4-channel, non-isolated, unipolar voltage/current, analog input plug-in module. As with all of the Bulletin 2080 plug-in modules, It can be plugged in the base unit of Micro820, Micro830 and Micro850 Controllers to extend its I/O functionality, without increasing the controller’s footprint (i.e no need for additional rack space).

Every channel on the Micro800 2080-IF4 can be configured for either unipolar (i.e positive only), current, or voltage input. This plug-in module is configured using the MS Windows based Connected Components Workbench™ software, which is also used to create and load the application program on the Micro800 Controllers. The configuration options available in the software for the Micro800 2080-IF4 include setting the sampling frequency (i.e how fast the measurement will be) for any individual channel to any of 50 Hz, 60 Hz, 250 Hz, 500 Hz values. Additionally, the user can choose either Voltage or Current inputs, or even disable a channel entirely.

Analog inputs of the Micro800 2080-IF4 can range from 0 to 10 Volts for voltage mode, and from 4 to 20 mA for current mode inputs, all at a 12-bit resolution, which means it can interpret measurements down to 2.44 mV for voltage, and .0049 mA for current. Analog inputs can be used to interface multiple types of sensors, devices and current-loop transmitters, which is a vital feature to receive the feedback signal in Closed Loop Control Systems (i. regulatory PID control systems), which are used in continuous process applications found in a number of industries (chemical, oil & gas, motion control, etc).

In addition, software-based high or low thresholds can be installed into Micro800 controllers that are enabled with a 2080-IF4 plug-in, in order to be able to monitor values for alarming and shut down purposes.

The ambient temperatures recommended for the Micro800 2080-IF4 operation are from -20 to 65 degrees Celsius (-4 to 149 degrees Fahrenheit).

Repair Services for 2080-IF4

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 2080-IF4. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 2080-IF4

Please refer to the manual for more information about the 2080-IF4 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2080-IF4 Ser A
2080-IF4/A, Series A, Rev A Request Quote
Common misspellings:
  • 2o80-IF4
  • 20b0-IF4
  • 208o-IF4
  • 2080-IFA
  • 2080IF4

Dimensions For 2080-IF4

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 2080-IF4

Resolutions For 2080-IF4

Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2080-IF4
Product TypeAnalog Plug-in Module
Module TypeAnalog
Number of Single-Ended Inputs4
Analog Normal Operating Voltage Range0-10V DC
Analog Normal Operating Current Range0-20mA
Data Range0-65535
Repeatability+/- 0.1%
Input Channel ConfigurationThrough Configuration Software or the User Program
Update Time180ms per Enabled Channel
Input Group to Bus Isolation/Channel to Channel IsolationNon-Isolation
Operating Altitude 2000m
Max. Cable Length10m
UPC10885630058396
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2080-IF4
Product TypeAnalog Plug-in Module
Module TypeAnalog
Number of Single-Ended Inputs4
Analog Normal Operating Voltage Range0-10V DC
Analog Normal Operating Current Range0-20mA
Data Range0-65535
Repeatability+/- 0.1%
Input Channel ConfigurationThrough Configuration Software or the User Program
Update Time180ms per Enabled Channel
Input Group to Bus Isolation/Channel to Channel IsolationNon-Isolation
Operating Altitude 2000m
Max. Cable Length10m
UPC10885630058396
About

The Allen Bradley Micro800 2080-IF4 module is a 4-channel, non-isolated, unipolar voltage/current, analog input plug-in module. As with all of the Bulletin 2080 plug-in modules, It can be plugged in the base unit of Micro820, Micro830 and Micro850 Controllers to extend its I/O functionality, without increasing the controller’s footprint (i.e no need for additional rack space).

Every channel on the Micro800 2080-IF4 can be configured for either unipolar (i.e positive only), current, or voltage input. This plug-in module is configured using the MS Windows based Connected Components Workbench™ software, which is also used to create and load the application program on the Micro800 Controllers. The configuration options available in the software for the Micro800 2080-IF4 include setting the sampling frequency (i.e how fast the measurement will be) for any individual channel to any of 50 Hz, 60 Hz, 250 Hz, 500 Hz values. Additionally, the user can choose either Voltage or Current inputs, or even disable a channel entirely.

Analog inputs of the Micro800 2080-IF4 can range from 0 to 10 Volts for voltage mode, and from 4 to 20 mA for current mode inputs, all at a 12-bit resolution, which means it can interpret measurements down to 2.44 mV for voltage, and .0049 mA for current. Analog inputs can be used to interface multiple types of sensors, devices and current-loop transmitters, which is a vital feature to receive the feedback signal in Closed Loop Control Systems (i. regulatory PID control systems), which are used in continuous process applications found in a number of industries (chemical, oil & gas, motion control, etc).

In addition, software-based high or low thresholds can be installed into Micro800 controllers that are enabled with a 2080-IF4 plug-in, in order to be able to monitor values for alarming and shut down purposes.

The ambient temperatures recommended for the Micro800 2080-IF4 operation are from -20 to 65 degrees Celsius (-4 to 149 degrees Fahrenheit).

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 2080-IF4. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your 2080-IF4. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 2080-IF4 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2080-IF4 Ser A
2080-IF4/A, Series A, Rev A Request Quote

Common misspellings:
  • 2o80-IF4
  • 20b0-IF4
  • 208o-IF4
  • 2080-IFA
  • 2080IF4
PDF