Product Type | Non-isolated Thermocouple and RTD Plug-in Module |
Mounting Torque | 0.2 Nm |
Terminal Screw Torque | 0.22-0.25 Nm |
Resolution | 14-bit |
Accuracy | +/- 1.0 *C for TC and RTD @ 25*C |
Channels | 2, Non-isolated |
Open Circuit Detection Time | 8-1515 ms |
Power Consumption | 3.3V, 40mA |
Input Impedance | > 300 K? |
CJC Error | +/-1.2 *C @ 25 *C |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 2080-TC2 |
Product Type | Non-isolated Thermocouple and RTD Plug-in Module |
Mounting Torque | 0.2 Nm |
Terminal Screw Torque | 0.22-0.25 Nm |
Resolution | 14-bit |
Accuracy | +/- 1.0 *C for TC and RTD @ 25*C |
Channels | 2, Non-isolated |
Open Circuit Detection Time | 8-1515 ms |
Power Consumption | 3.3V, 40mA |
Input Impedance | > 300 K? |
CJC Error | +/-1.2 *C @ 25 *C |
The 2080-TC2 by Allen-Bradley is a 2-channel, non-isolated thermocouple plug-in model that belongs to the Micro800 Specialty Plug-in Modules. It enhances the range of capabilities of a base unit controller by making temperature control possible when a Proportional Integral Derivative is used. Micro830 and Micro850 support this specialty module. It can be installed on any of the controller plug-in slots. The module unit ships with two module fastening screws, a pin-out guide wiring instructions, and one EPCOS B57869S0502F140 part, which is a passive negative temperature, non-polarized co-efficient CJC thermistor that is fixed to the plug-in. Be careful not to unscrew or remove this CJC thermistor.
The 2080-TC2 Thermocouple Plug-in Module has 12-pin female terminal blocks and supports sensors with ANSI and IEC code B, E, J, K, N, R, S, and T. It has a 14-bit resolution, a power consumption of 3.3 Volts, 40 mA, and an input impedance of 300 KΩ. It comes with a common mode rejection ratio of 100 dB at 50 to 60 Hertz, and normal mode rejection ratio of 70 dB at 50 to 60 Hertz. Using a 2.5 millimeter or 0.10-inch flat-blade screwdriver, apply terminal screw torque between 0.22 and 0.25 N-m (1.95 to 2.21 pounds on an inch). The plug-in can be wired before insertion into the controller or once it has been secured in place.
Cabling used with the 2080-TC2 Module must be shielded, twisted cores. At the controller end, the shield wire should be shorted to a chassis ground. The recommended wire size is between 0.14 and 1.0 millimeters squared (26 to 17 AWG) stranded copper wire or 0.14 to 1.5 millimeters squared (26 to 16 AWG) solid copper wire, both of which should be rated at a maximum insulation of 90 degrees Celsius (194 degrees Fahrenheit). Performance of the non-isolated module and entire setup will depend on the application, however, better noise immunity can be achieved by keeping cable length within the ideal length of ten meters. If working with configurations requiring longer cable length, use the 2085 expansion I/O modules.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 2080-TC2. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 2080-TC2 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
2080-TC2 Ser A |
2080-TC2/A, Series A, Rev A | Request Quote |
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 2080-TC2 |
Product Type | Non-isolated Thermocouple and RTD Plug-in Module |
Mounting Torque | 0.2 Nm |
Terminal Screw Torque | 0.22-0.25 Nm |
Resolution | 14-bit |
Accuracy | +/- 1.0 *C for TC and RTD @ 25*C |
Channels | 2, Non-isolated |
Open Circuit Detection Time | 8-1515 ms |
Power Consumption | 3.3V, 40mA |
Input Impedance | > 300 K? |
CJC Error | +/-1.2 *C @ 25 *C |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 2080-TC2 |
Product Type | Non-isolated Thermocouple and RTD Plug-in Module |
Mounting Torque | 0.2 Nm |
Terminal Screw Torque | 0.22-0.25 Nm |
Resolution | 14-bit |
Accuracy | +/- 1.0 *C for TC and RTD @ 25*C |
Channels | 2, Non-isolated |
Open Circuit Detection Time | 8-1515 ms |
Power Consumption | 3.3V, 40mA |
Input Impedance | > 300 K? |
CJC Error | +/-1.2 *C @ 25 *C |
The 2080-TC2 by Allen-Bradley is a 2-channel, non-isolated thermocouple plug-in model that belongs to the Micro800 Specialty Plug-in Modules. It enhances the range of capabilities of a base unit controller by making temperature control possible when a Proportional Integral Derivative is used. Micro830 and Micro850 support this specialty module. It can be installed on any of the controller plug-in slots. The module unit ships with two module fastening screws, a pin-out guide wiring instructions, and one EPCOS B57869S0502F140 part, which is a passive negative temperature, non-polarized co-efficient CJC thermistor that is fixed to the plug-in. Be careful not to unscrew or remove this CJC thermistor.
The 2080-TC2 Thermocouple Plug-in Module has 12-pin female terminal blocks and supports sensors with ANSI and IEC code B, E, J, K, N, R, S, and T. It has a 14-bit resolution, a power consumption of 3.3 Volts, 40 mA, and an input impedance of 300 KΩ. It comes with a common mode rejection ratio of 100 dB at 50 to 60 Hertz, and normal mode rejection ratio of 70 dB at 50 to 60 Hertz. Using a 2.5 millimeter or 0.10-inch flat-blade screwdriver, apply terminal screw torque between 0.22 and 0.25 N-m (1.95 to 2.21 pounds on an inch). The plug-in can be wired before insertion into the controller or once it has been secured in place.
Cabling used with the 2080-TC2 Module must be shielded, twisted cores. At the controller end, the shield wire should be shorted to a chassis ground. The recommended wire size is between 0.14 and 1.0 millimeters squared (26 to 17 AWG) stranded copper wire or 0.14 to 1.5 millimeters squared (26 to 16 AWG) solid copper wire, both of which should be rated at a maximum insulation of 90 degrees Celsius (194 degrees Fahrenheit). Performance of the non-isolated module and entire setup will depend on the application, however, better noise immunity can be achieved by keeping cable length within the ideal length of ten meters. If working with configurations requiring longer cable length, use the 2085 expansion I/O modules.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 2080-TC2. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 2080-TC2. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 2080-TC2 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
2080-TC2 Ser A |
2080-TC2/A, Series A, Rev A | Request Quote |