DO Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with DO Supply's 1-year warranty
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Description: The 1766-L32BWA is a MicroLogix 1400 Controller under the Bulletin 1766 product family. This compact controller features integrated Three (3) communication ports such as a combo RS232 / RS485 port, isolated RS232 port and an Ethernet communication port. It has embedded Input and Output channels which consists of Twelve (12) Fast 24V DC, Eight (8) Normal 24V DC Inputs, and Twelve (12) Relay outputs. This content was written and compiled by DO Supply and should not be copied.
DO Supply is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with DO Supply's 1-year warranty
Rockwell Disclaimer: The product is used surplus. DO Supply is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because DO Supply is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. DO Supply also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. DO Supply also makes no representations as to your right to install any such firmware on the product. DO Supply will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via UPS, DHL, and TNT |
Repairs: | We offer repair service for the 1766-L32BWA. |
Exchange: | Exchange credit for your defective unit available. |
Conditions: | We sell preowned surplus and refurbished parts. |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1766-L32BWA |
Product Family: | MicroLogix |
Series | MicroLogix 1400 |
Product Type: | MicroLogix 1400 Controller |
Module Type | Controller |
Inputs | (12) Digital Fast 24V DC, (8) Digital Normal 24V DC |
Number of I/O: | 32 points |
Outputs | (12) Relay |
Operating Power | 110-240V AC |
Number of Discrete Inputs: | Twenty (20) 120VAC |
Analog Input Signal Range: | None |
Channel Count | (20) IP, (12) OP |
Number of Discrete Outputs: | Twelve (12) Relay |
Memory | 20 KB |
Feature | Built-in RTC |
Power supply: | 100/240V AC |
Weight | 2 lbs |
Input power | 100 to 240 VAC |
Operating Frequency: | 47-63 Hz |
Power Consumption: | 120 VA |
Wire Size | 22 to 14 AWG |
Power supply inrush current | 120V AC: 25 A for 8 ms 240V AC: 40A for 4 ms |
Cable length | 30m |
Resolution | 12 bit |
Communication port: | 1 RS232 / RS485; 1 Ethernet; 1 RS232 |
UPC | 10612598518101 |
Supported Protocols: | Serial: DF1, ASCII, MODBUS RTU, DNP3, DH485 Ethernet: Ethernet I/P, DNP3, MODBUS TCP/IP |
UNSPSC | 32151705 |
Dimensions: | 90 x 180 x 87 mm (3.5 x 7.087 x 3.43 in) |
Mounting: | Panel Mounting / DIN Rail |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1766-L32BWA |
Product Family: | MicroLogix |
Series | MicroLogix 1400 |
Product Type: | MicroLogix 1400 Controller |
Module Type | Controller |
Inputs | (12) Digital Fast 24V DC, (8) Digital Normal 24V DC |
Number of I/O: | 32 points |
Outputs | (12) Relay |
Operating Power | 110-240V AC |
Number of Discrete Inputs: | Twenty (20) 120VAC |
Analog Input Signal Range: | None |
Channel Count | (20) IP, (12) OP |
Number of Discrete Outputs: | Twelve (12) Relay |
Memory | 20 KB |
Feature | Built-in RTC |
Power supply: | 100/240V AC |
Weight | 2 lbs |
Input power | 100 to 240 VAC |
Operating Frequency: | 47-63 Hz |
Power Consumption: | 120 VA |
Wire Size | 22 to 14 AWG |
Power supply inrush current | 120V AC: 25 A for 8 ms 240V AC: 40A for 4 ms |
Cable length | 30m |
Resolution | 12 bit |
Communication port: | 1 RS232 / RS485; 1 Ethernet; 1 RS232 |
UPC | 10612598518101 |
Supported Protocols: | Serial: DF1, ASCII, MODBUS RTU, DNP3, DH485 Ethernet: Ethernet I/P, DNP3, MODBUS TCP/IP |
UNSPSC | 32151705 |
Dimensions: | 90 x 180 x 87 mm (3.5 x 7.087 x 3.43 in) |
Mounting: | Panel Mounting / DIN Rail |
What type of input does this module have?
The 1766-L32BWA has twelve (12) Digital Fast inputs and eight (8) Digital Normal inputs.
What type of memory does the 1766-L32BWA module use?
The 1766-L32BWA comes equipped with a 20 KB memory.
Can this module be purchased with a warranty?
Yes, the 1766-L32BWA comes with a free one-year warranty from DO Supply, Inc.
Where can I send the 1766-L32BWA to be repaired?
DO Supply, Inc. offers a variety of repair services for the 1766-L32BWA.
This Micro-Logix processor is capable of controlling 20 inputs and 12 outputs with a built-in 24v DC power supply. This device can be communicated with through either the 9 or 8 pin RS-232 cable as well as via EtherNet. The LCD will display I/O status as well as change processor modes and much more. The 1766-L32BWA is powered by 120-240v AC at 50-60 Hz.
NOTE : Ensure that your program is saved or backed up before ever removing power from a processor.
LCD can malfunction but the processor will still be functional.
Visual inspection of components which may be damaged.
Ensure terminal blocks are screwed in and terminating adequately.
EtherNet port will have a green light illuminated when connected to the network and an orange flickering light when communicating to the network.
No Communications? Unplug the battery and processor for 2-5 min and try again
Check each communications port for visual damage
Ensure communications cable is in operable condition
Check publication for led indicators meaning and LCD controls
Apply power to the processor and test 24v DC out with a voltmeter
Both 8 pin and 9 pin ports will auto-configure in RS-Linx (Driver: RS-323 DF1 devices)
With power off, add the expansion card then power back on to see if the card is seen in I/O configuration
Ethernet once configured the IP will come up in RS-Linx
Test inputs by applying 24v DC through each input
(black lead is 24v com and red lead is 24v positive going to input 0, each input will toggle on the LCD display as well as in the input table of the program)
Using an ohmmeter test outputs in the on and off state
(in the off state outputs will read OL or 0 depending on the meter, in the on state the output will read a very low ohm reading.)
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 1766-L32BWA. Please contact us for additional details about our repair process.
Please refer to the manual for more information about the 1766-L32BWA such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
1766-L32BWA Ser A
|
1766-L32BWA/A, Series A, Rev A | Request Quote |
1766-L32BWA Ser B
|
1766-L32BWA/B, Series B, Rev B | Request Quote |
1766-L32BWA Ser C
|
1766-L32BWA/C, Series C, Rev C | Request Quote |
"The 1761-L32BWA is a MicroLogix 1400 controller that features a high-density number of standard inputs and outputs. Specifically, this controller has Twelve (12) Fast 24V DC, Eight (8) Normal 24V DC Inputs, and Twelve (12) Relay outputs. Compared to the 1766-L32AWA, the 1766-L32BWA supports high-speed input which enables this controller to be used in applications that is involved in counting or totalizing functions. Some applications that require such function are production counters and material flow monitoring. " -DO Supply Tech
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1766-L32BWA |
Product Family: | MicroLogix |
Series | MicroLogix 1400 |
Product Type: | MicroLogix 1400 Controller |
Module Type | Controller |
Inputs | (12) Digital Fast 24V DC, (8) Digital Normal 24V DC |
Number of I/O: | 32 points |
Outputs | (12) Relay |
Operating Power | 110-240V AC |
Number of Discrete Inputs: | Twenty (20) 120VAC |
Analog Input Signal Range: | None |
Channel Count | (20) IP, (12) OP |
Number of Discrete Outputs: | Twelve (12) Relay |
Memory | 20 KB |
Feature | Built-in RTC |
Power supply: | 100/240V AC |
Weight | 2 lbs |
Input power | 100 to 240 VAC |
Operating Frequency: | 47-63 Hz |
Power Consumption: | 120 VA |
Wire Size | 22 to 14 AWG |
Power supply inrush current | 120V AC: 25 A for 8 ms 240V AC: 40A for 4 ms |
Cable length | 30m |
Resolution | 12 bit |
Communication port: | 1 RS232 / RS485; 1 Ethernet; 1 RS232 |
UPC | 10612598518101 |
Supported Protocols: | Serial: DF1, ASCII, MODBUS RTU, DNP3, DH485 Ethernet: Ethernet I/P, DNP3, MODBUS TCP/IP |
UNSPSC | 32151705 |
Dimensions: | 90 x 180 x 87 mm (3.5 x 7.087 x 3.43 in) |
Mounting: | Panel Mounting / DIN Rail |
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1766-L32BWA |
Product Family: | MicroLogix |
Series | MicroLogix 1400 |
Product Type: | MicroLogix 1400 Controller |
Module Type | Controller |
Inputs | (12) Digital Fast 24V DC, (8) Digital Normal 24V DC |
Number of I/O: | 32 points |
Outputs | (12) Relay |
Operating Power | 110-240V AC |
Number of Discrete Inputs: | Twenty (20) 120VAC |
Analog Input Signal Range: | None |
Channel Count | (20) IP, (12) OP |
Number of Discrete Outputs: | Twelve (12) Relay |
Memory | 20 KB |
Feature | Built-in RTC |
Power supply: | 100/240V AC |
Weight | 2 lbs |
Input power | 100 to 240 VAC |
Operating Frequency: | 47-63 Hz |
Power Consumption: | 120 VA |
Wire Size | 22 to 14 AWG |
Power supply inrush current | 120V AC: 25 A for 8 ms 240V AC: 40A for 4 ms |
Cable length | 30m |
Resolution | 12 bit |
Communication port: | 1 RS232 / RS485; 1 Ethernet; 1 RS232 |
UPC | 10612598518101 |
Supported Protocols: | Serial: DF1, ASCII, MODBUS RTU, DNP3, DH485 Ethernet: Ethernet I/P, DNP3, MODBUS TCP/IP |
UNSPSC | 32151705 |
Dimensions: | 90 x 180 x 87 mm (3.5 x 7.087 x 3.43 in) |
Mounting: | Panel Mounting / DIN Rail |
What type of input does this module have?
The 1766-L32BWA has twelve (12) Digital Fast inputs and eight (8) Digital Normal inputs.
What type of memory does the 1766-L32BWA module use?
The 1766-L32BWA comes equipped with a 20 KB memory.
Can this module be purchased with a warranty?
Yes, the 1766-L32BWA comes with a free one-year warranty from DO Supply, Inc.
Where can I send the 1766-L32BWA to be repaired?
DO Supply, Inc. offers a variety of repair services for the 1766-L32BWA.
This Micro-Logix processor is capable of controlling 20 inputs and 12 outputs with a built-in 24v DC power supply. This device can be communicated with through either the 9 or 8 pin RS-232 cable as well as via EtherNet. The LCD will display I/O status as well as change processor modes and much more. The 1766-L32BWA is powered by 120-240v AC at 50-60 Hz.
NOTE : Ensure that your program is saved or backed up before ever removing power from a processor.
LCD can malfunction but the processor will still be functional.
Visual inspection of components which may be damaged.
Ensure terminal blocks are screwed in and terminating adequately.
EtherNet port will have a green light illuminated when connected to the network and an orange flickering light when communicating to the network.
No Communications? Unplug the battery and processor for 2-5 min and try again
Check each communications port for visual damage
Ensure communications cable is in operable condition
Check publication for led indicators meaning and LCD controls
Apply power to the processor and test 24v DC out with a voltmeter
Both 8 pin and 9 pin ports will auto-configure in RS-Linx (Driver: RS-323 DF1 devices)
With power off, add the expansion card then power back on to see if the card is seen in I/O configuration
Ethernet once configured the IP will come up in RS-Linx
Test inputs by applying 24v DC through each input
(black lead is 24v com and red lead is 24v positive going to input 0, each input will toggle on the LCD display as well as in the input table of the program)
Using an ohmmeter test outputs in the on and off state
(in the off state outputs will read OL or 0 depending on the meter, in the on state the output will read a very low ohm reading.)
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 1766-L32BWA. Please contact us for additional details about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 1766-L32BWA. Please contact us for additional details about our repair process.
Please refer to the manual for more information about the 1766-L32BWA such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
1766-L32BWA Ser A
|
1766-L32BWA/A, Series A, Rev A | Request Quote |
1766-L32BWA Ser B
|
1766-L32BWA/B, Series B, Rev B | Request Quote |
1766-L32BWA Ser C
|
1766-L32BWA/C, Series C, Rev C | Request Quote |
"The 1761-L32BWA is a MicroLogix 1400 controller that features a high-density number of standard inputs and outputs. Specifically, this controller has Twelve (12) Fast 24V DC, Eight (8) Normal 24V DC Inputs, and Twelve (12) Relay outputs. Compared to the 1766-L32AWA, the 1766-L32BWA supports high-speed input which enables this controller to be used in applications that is involved in counting or totalizing functions. Some applications that require such function are production counters and material flow monitoring. " -DO Supply Tech