The Allen-Bradley 1771-P4R is a redundant power supply module that is used with the 1771 Programmable Logic Controller (PLC) range. This module operates at an input supply voltage range of 97-132 Volts AC along a frequency of 47-63 Hertz. It has an output voltage to the backplane of 5 Volts DC and an output current of 8 Amperes. It occupies a single slot of the chassis and comes with an integral 1.5 Ampere, 250 Volt AC slow blow fuse.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Category | PLCs |
| Product Line | PLC 5 |
| Part Number | 1771-P4R |
| UPC | 612598003570 |
| Weight | 2.00 lbs (0.91 kg) |
| Input Voltage Range | 97-132 VAC |
| Module Type | Redundant Power Supply |
| Input voltage frequency | 47-63 Hz |
| Output voltage | 5 VDC |
| Output current | 8:00 AM |
| Maximum output current at 60o C using N+1 Redundancy | 8A (2 unit system); 14A (3 unit system); 20A (4 unit system) |
| Alarm Relay Rating | 250 VAC |
| Wiring Block, AC power | A-B part number 941274-05 (Wago PN 231-205/000-008) |
| Wiring Block, Relay | A-B part number 941274-03 (Wago PN 231-203/000-008) |
| Operating temperature | 32 to 131oF |
| Storage Temperature | -40 to 185oF |
| Relative Humidity | 5-95 % |
| Nom Input Voltage | 120 Volts AC |
| Max Real Input Power | 59 Watts |
| Max Apparent Input Power | 92 VA |
| Max Xformer Load | 148 VA |
| User Output Current | N/A |
| Backplane Output Current | 8 Amperes (at 5 Volts DC) |
| Frequency | 47-63 Hertz |
| Fuse | 1.5 Amperes, 250 Volts, slow-blow |
| Cabling | Redundancy Cable for P4R (Included) |
| Paralleled | N/A |
| Location | 1771 Chassis, 1 Slot |
The 1771-P4R PLC 5 Redundant Power Supply Module by Allen-Bradley is an electrical device located in the 1771 Chassis which increases system availability and reduces machine downtime resulting from a failed power supply in the system. It prevents system interruption or complete shutdown of the system’s operations when there is a power failure. The 1771-P4R has an input voltage range of 97-132V AC at 50-60Hz and provides a 5V DC output current at 8A. The module has a N+1 design feature and the maximum output current provided by the module using N+1 at 60 degrees Celsius is 8A (for a 2-unit system), 14A (for a 3-unit system), and 20A (for a 4-unit system). Its 16W maximum power dissipation with a 10W dissipation on the adjacent slot and with a 47.8 BTU/hr maximum thermal dissipation. The 1771-P4R module provides a 300mA backplane current at 5V DC and is tested to withstand 1000V voltage isolation for 1 second. The 1771-P4R circuitry uses the 2.5mm2 copper wire size with 3/64-inch insulation thickness rated at 60 degrees Celsius and is shipped with a redundancy cable. It provides a 15A branch circuit protection and it also provides circuit protection through the 1.5A 250V AC Slow Blow fuse and with the Bussman MDL 1.5 fuse. The module has an alarm circuit with a rating of 24-250V AC, 1/6HP, 1A, and 30V DC. The 1771-P4R has a tested working temperature range between 0 and 60 degrees Celsius at 5-95% non-condensing relative humidity, without de-rating, and is CSA, NEMA, and UL-certified.
The Allen-Bradley 1771-P4R is a Power Supply module that is used with the 1771 Programmable Logic Controller (PLC) product family. This module is specifically used to increase the system uptime and availability as it allows pairing to another 1771-P4R, providing an additional layer of protection along the power supply line. With a redundant power supply configuration, the power supply units operate simultaneously with one unit’s output relegated as standby source. When the active power supply unit fails or shuts down, the secondary active supply takeover, preventing unwanted stoppage or shutdown to the system.
The 1771-P4R operates when supplied with an input voltage range of 97-132 Volts AC with a frequency of 47-73 Hertz. It delivers an output voltage to the backplane of 5 Volts DC and an output current of 8 Amperes. It comes with an integral fuse with 1.5 Amperes, 250 Volts AC rating. This module occupies only a single slot of the 1771 chassis. Additionally, it comes with an output alarm that is rated 250 Volts AC.
The 1771-P4R is designed for maximum system output current of 8 Amperes for a 2 unit system; 14 Amperes for a 3 unit system and 20 Amperes for a 4 unit system. These ratings are within 60 degrees Celsius operating environment using N+1 Redundancy.
Wiring to this module is terminated to the module’s wiring blocks. Allen-Bradley wiring blocks for this module have Allen-Bradley part number 941274-05 and equivalent Wago part number of 231-205 / 000-008. Additionally, relay wiring blocks for use with this power supply is 941274-03 with equivalent Wago part number of 231-203 / 000-008.
| Revision Part # | Also known as | |
|---|---|---|
| 1771-P4R Ser A | 1771-P4R/A, Series A, Rev A | |
| 1771-P4R Ser B | 1771-P4R/B, Series B, Rev B | |
| 1771-P4R Ser C | 1771-P4R/C, Series C, Rev C | |
| Don't see your particular revision? Contact us now. | ||
Yes, the 1771-P4R includes a free 2-year DO Supply warranty. You can upgrade to a 3-year warranty at checkout for even more protection.
The input voltage requirement of the 1771-P4R is 97-132 VAC.
The output current and voltage of the 1771-P4R are 8 A and 5VDC.
Yes. It has an Alarm 250 VAC alarm relay.
Allen Bradley PLC 5 Power Supply, 120 Volts AC Nom Input Voltage, 97-132 Volts AC Input Voltage Range, 8 Amperes (at 5 Volts DC) Backplane Output Current