The Allen-Bradley 1404-M505A-ENT module is a PowerMonitor 3000 master module. It has a power rating of 120 to 240 Volts AC and a frequency rating of 50 to 60 Hertz.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Category | PLCs |
| Product Line | PowerMonitor 3000 |
| Part Number | 1404-M505A-ENT |
| UPC | 611320609547 |
| Weight | 2.06 lbs (0.94 kg) |
| Communication Rate | 10/100 Mbps |
| Concurrent Connections | 64 CIP/HTTP |
| Data read latency | less than 10 ms |
| Update rates for real-time metering data | 100 ms minimum |
| Update rates for logged data | 250 ms minimum |
| Communication Ports | RS-485 and 10/100 BaseT Ethernet |
| Power Rating | 120/240V |
| Amperage Rating | 5 A |
| Frequency Rating | 0- 60 Hz |
| Operating Temperature | 0 - 50 degrees Celsius (32 - 131 degrees Fahrenheit) |
| Storage Temperature | -40 - 85 degrees Celsius (-40 - 185 degrees Fahrenheit) |
| Humidity | 5 - 95%. |
| Vibration | 10-500 Hz: 2 g Operational (±0.012 in.) |
| Shock | 1/2 Sine Pulse, 11 ms duration: 30 g Operational and 30 g Nonoperational |
The 1404-M505A-ENT PowerMonitor 3000 module by Allen-Bradley/Rockwell Automation has the letters "ENT" at the end of its catalog number to indicate that it not only has a native RS-485 communication port but also an active 10/100 BaseT Ethernet communication port. The Ethernet port can connect to the Allen-Bradley 1761-NET-ENI, ControlLogix Ethernet Bridge, PLC-5E, and SLC 5/05 controllers. The users can use it with other network switches, bridges, hubs, and routers too.
The Allen-Bradley 1404-M505A-ENT module has a dual-port configuration, which makes the communication ports (the RS-485 and 10/100 BaseT Ethernet ports) able to operate concurrently. Before connecting the Ethernet network to the PowerMonitor module, the communication parameters should be configured. The parameters that need to be configured include the Subnet Mask, Gateway IP address, and Internet Protocol (IP) address configurations. Configure the IP address to enable the easy identification of the 1404-M505A-ENT PowerMonitor module on the network. Use the 4 decimal numbers and set each octet or byte ranging from 0 to 255 decimal, for instance, aaa.bbb.ccc.ddd. Set "192.168.254x" as the default IP address, where "x" is the unit’s ID number that is assigned by the manufacturer. Note that some IP addresses are not allowed such as "255.255.255.255." This PowerMonitor 3000 monitor has a power rating of 120/240 Volts AC, a current rating of 5 Amps, and a frequency rating of 50 to 60 Hertz.