The 1747-L531 is an SLC 5/03 controller module for the SLC 500 Modular Hardware by Allen-Bradley. It comes with Memory of 8KB, and built-in communication interfaces such as RS-232 Port and DH485 communication port. It has IO capacity of 4096 Discrete IO points with typical scan time of 1 ms/K.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.
Repair and exchange services for all existing automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Manufacturer | Rockwell Automation |
---|---|
Brand | Allen-Bradley |
Part Number/Catalog No. | 1747-L531 |
Series | SLC 500 |
Inputs | 4096 |
Module Type | SLC 5/03 Processor |
Outputs | 4096 |
Analog I/O | 180 |
Memory: | Up to 8 KB, Battery Backed-RAM |
Program Scan Time | 1 ms/K |
User Memory | 8,000 Words |
I/O Chassis | 3 |
Chassis Module Slots | 30 |
I/O Scan Time | 0.225 milliseconds |
Communication | DH485, RS-232 |
Backup Memory | 1747-M13 |
Ambient Temperature | 0 to 60 degrees Celsius |
Backplane Current (5 Volts DC) | 500 milliamps |
Battery back-up memory: | Yes; 1747-BA |
UPC | 10662072666279 |
The Allen-Bradley 1747-L531 is an SLC 5/03 processor type module that belongs to the SLC 500 Modular Hardware Style series. It is built to perform a large variety of functions, including small, simple stand-alone systems to large, complex distributed ones. Designed to perform throughput, it can support 60 various I/O modules including analog, digital, and intelligent I/O’s and can, in addition, control up to 4,096 output and input points. It ships with the SLC 500 modular processor, a compatible chassis, power supplies, and installation instructions for all the included parts. This module is C-Tick marked, CE compliant, and UL listed to Canadian and US Safety Standards,
The 1747-L531 Modular Processor comes with a memory size of 8 K, 16 K, or 32 K for its programs. This user-configurable memory can be applied either to program storage or to data storage. The drive features a battery-backed RAM that lasts approximately 2 years. The BATT LED indicator alerts user when the voltage of the replaceable battery has fallen below the threshold level. A minimum of thirty (30) minutes of power is available when the battery is disconnected, due to an integrated capacitor. If a new battery is installed to replace the old one within half an hour (30 minutes), any data stored in the RAM can be retained. The 1747-L531 Processor receives and initiates communication protocols including DH-485 peer-to-peer, ControlNet, Ethernet, Data Highway Plus (DH+), DeviceNet, Modbus RTU Master, as well as full-duplex or half-duplex master or slave DF1, ASCII and DH-485 via the RS232 port. Its front panel has a 3-position key switch that allows three operation modes: PROGRAM, RUN, and REMOTE. This key switch cannot be used in place of an emergency-stop switch or a hardwired master control relay.
This controller has an integrated 8K memory, which can be expanded with the use of a Flash EPROM. The required memory module has part number of 1747-M13 and adapter socket of 1747-M15 that supports up to 64K of user memory. User program can be stored or burned to the memory module to prevent accidental or unwanted program deletion that may be caused by improper programming, electrical surges and noises. The general rule when burning user program to the memory module is that the program size must not exceed the processor memory size. Do not burn a faulted program, especially a program with a major fault. This will include the fault condition and cause of the fault to be burned in the EPROM.
User programs, hardware configuration are implemented here as well as commissioning and troubleshooting tool are available such as I/O forcing.
This processor also supports hold-up time feature. This refers to the processor’s ability to continue programming scanning for a limited time even if the input voltage to the system power supply falls below the nominal range. When the hold-up time expire, the CPU is automatically put to stop mode. This prevents sudden stoppage that is not ideal in any control application.
Revision Part # | Also known as | |
---|---|---|
1747-L531 Ser A | 1747-L531/A, Series A, Rev A | Request a quote |
1747-L531 Ser B | 1747-L531/B, Series B, Rev B | Request a quote |
1747-L531 Ser C | 1747-L531/C, Series C, Rev C | Request a quote |
1747-L531 Ser D | 1747-L531/D, Series D, Rev D | Request a quote |
1747-L531 Ser E | 1747-L531/E, Series E, Rev E | Request a quote |
Don't see your particular revision? Contact us now. |
Our highly skilled technicians can repair your SLC 500 1747-L531. All of our repairs come with a 1 Year Warranty. Please contact us for additional information.
Yes, the 1747-L531 comes with a free one-year warranty from DO Supply, Inc.
DO Supply, Inc. offers a variety of repair services for the 1747-L531.
The 1747-L531 uses DH-485 and RS-232 communication.
The 1747-L531 has a user memory of around 8,000 words and a flash backup memory.
The Allen-Bradley 1747-L531 is a SLC 500 SLC 5/03 Processor. This SLC 5/03 Processor has 4096 Inputs points and 4096 Outputs points with an Analog I/O of 180.
The highest amount of attachable I/O obtained by the SLC 500 series.
The very best when it comes to attachable analog on the SLC 500 series.
A Fair amount of memory for the price, adaptable memory modules are available for sale.
Not the absolute fastest scan time, but a very close second with a difference of only milliseconds.
The 1747-L531 is SLC 5/03 processor that is very much identical with the technical feature of 1747-L532. The main difference between these 2 processors is that the 1747-L531 has lower amount of integrated memory, that is half or 8KB memory only. 1747-L531 is the least processor among the 3 variants under SLC 5/03 category.