The 1747-L541 is a controller module for the SLC 500 Modular Hardware by Allen-Bradley. It comes with Memory or 32 KB, and built-in communication interfaces such as 9-Pin RS-232 and Data Highway Plus (DH+). It is capable of 4096 Inputs points and 4096 Outputs points with an Analog I/O count of 480 point.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.
Repair and exchange services for all existing automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Manufacturer | Rockwell Automation |
---|---|
Brand | Allen-Bradley |
Part Number/Catalog No. | 1747-L542 |
Series | SLC 500 |
Inputs | 4096 |
Module Type | SLC 5/04 Processor |
Outputs | 4096 |
Analog I/O | 480 |
Memory: | Up to 32 KB, Battery Backed-RAM |
Program Scan Time | 0.9 ms/K |
User Memory | 32,000 Words |
I/O Chassis | 3 |
Chassis Module Slots | 30 |
I/O Scan Time | 0.225 milliseconds |
Communication | Data Highway Plus (DH+), RS-232 |
Ambient Temperature | 0 to 60 degrees Celsius |
Backup Memory | 1747-M13 |
Battery back-up memory: | Yes; 1747-BA |
UPC | 10662468417454 |
UNSPSC | 32151705 |
The 1747-L542 SLC is an SLC 5/03 controller. This controller is one of the Three (3) controllers under the 1747-L52 SLC 5/03 category. This controller is the mid-range controller of SLC 5/03 which has 32 KB user memory while still capable of handling 4096 Input and outputs.
The 1747-L542 is used with the modular style hardware. This processor is installed to slot Zero (0) of any SLC chassis such as 1746-A2, 1746-A7, 1746-A10 and 1746-A13. It is powered though the power supplied in the backplane, provided by the system power supply installed at the leftmost area of the chassis.
This SLC processor has integrated RS232 and Data Highway Plus (DH+) communication port which allows this processor to be communicated with computer-based control systems such as Human Machine Interface (HMI) or Supervisory Control and Data Acquisition (SCADA). This processor may also be used for messaging or implement pass-through communication for other Allen-Bradley Programable Logic Controller (PLC) such as PLC 5, CompactLogix and ControlLogix platforms.
This processor is built with status indicators such as Run, CPU Fault, Forced I/O, Battery Low, RS-232 and DH+ LEDs. It is also provided with a key for switching the processor’s operating mode. The Allen-Bradley 1747-L542 is an SLC 500 SLC 5/04 modular processing unit that has the capacity to handle 32K words, specifically 4K data storage and 28K words for program data. It has an absolute maximum of 4096 discrete inputs and 4096 discrete outputs, with 480 maximum local analog I/O. The 1747-L542 also has a maximum of 3 local I/O chassis, with a maximum of 30 slots in the local I/O chassis. Its I/O scan time is 0.255 milliseconds, typical program scan time is 0.9 milliseconds/Kword, and bit execution time is 0.37 milliseconds, with a program scan holdup time of 20 milliseconds to 3 seconds after a power loss.
The power scan hold-up time depends on the loading of the power supply. It also uses a Flash EPROM for its memory back-up and the 32KB RAM of the 1747-L542 processor is battery-backed. Communication ports present are an RS-232 port and a DH+ port. Status LEDs are also available, specifically for low battery, CPU fault, run, forced I/O, DH+, and RS-232. The 1747-L542’s backplane current is 1 A at 5 Volts DC and the current is 175 mA at 24 Volts DC. It operates at a temperature between 32 - 140 degrees Fahrenheit and it can be stored at a temperature between -40- and 185-degrees Fahrenheit, with an ambient relative humidity of 5 to 95%, non-condensing. This processor’s acceleration is 2.5G at 57 to 2000 Hertz, its displacement is 0.015 inches, peak-to-peak, at 5 to 57 Hertz, and its operating shock is 30G.
Revision Part # | Also known as | |
---|---|---|
1747-L542 Ser A | 1747-L542/A, Series A, Rev A | Request a quote |
1747-L542 Ser B | 1747-L542/B, Series B, Rev B | Request a quote |
1747-L542 Ser C | 1747-L542/C, Series C, Rev C | Request a quote |
1747-L542 Ser D | 1747-L542/D, Series D, Rev D | Request a quote |
Don't see your particular revision? Contact us now. |
Our highly skilled technicians can repair your SLC 500 1747-L542. All of our repairs come with a 1 Year Warranty. Please contact us for additional information.
The 1747-L542's ambient relative humidity is 5 to 95%.
The 1747-L542's ambient operating temperature is 32 to 140 degrees Fahrenheit.
The 1747-L542 can withstand 30G of operating shock.
The 1747-L542 has 32KB of RAM.
The 1747-L542 can support up to 3 I/O chassis?
Yes, the 1747-L542 is battery-backed.
The Allen-Bradley 1747-L542 is a SLC 500 SLC 5/04 Processor. This SLC 5/04 Processor has 4096 Inputs points and 4096 Outputs points with an Analog I/O of 480.
This processor has the highest amount of attachable Inputs/Outputs in the SLC 500 series.
This unit is the very best when it comes to attachable analog on the SLC 500 series.
Not the most memory available, but coming in with 4 stars, the memory is still adequate for almost any operation
Scan time is outrageously fast, ranking in as one of the fastest processors in the SLC 500 Series.
The 1747-L542 is SLC 5/04. When it comes to IO capacity, this controller is superior when compared to a 1747-L511 processor. The 1747-L541 has 32K memory compared to 1747-L514 which only has 4K memory. This processor can also accommodate 4096 IO while the 1747-L511 is capable only of 3940 Discrete I/O.