2711P-K4M3A

thumbnail 1
 
thumbnail 2
Rated 4.4 with 8 reviews

top legal disclaimer
credit cards accepted
better business bureau

2711P-K4M3A

Description: The Panelview Plus 400 has a 3.5 inch Grayscale Display and a Keypad it is AC Powered and communicates via a DH-485 Port
Available Now
Request a quote for 2711P-K4M3A

Description: The Panelview Plus 400 has a 3.5 inch Grayscale Display and a Keypad it is AC Powered and communicates via a DH-485 Port

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2711P-K4M3A.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
phone

International
919-205-4392

Rated 4.4 with 8 reviews


About 2711P-K4M3A

The Allen-Bradley 2711P-K4M3A PanelView™ Plus 4 is a real-time monitoring terminal. The 2711P-K4M3A has a display size of 3.5 inches. This module has a keypad input. The display shows information graphically and operators can control it easily because this module is user-friendly. Besides the display module, there are also a logic module and a communication module. The Allen Bradley 2711P-K4M3A has a replaceable battery. The battery life is 4 years minimum at 25 °C. Be sure to remove the power before removing or replacing the battery. The 2711P-K4M3A module has a flash memory of 64 MB and 64 MB of RAM (PC100 SDRAM SODIMM 800 MiB/s peak).


The Allen-Bradley 2711P-K4M3A PanelView™ Plus 4 comes with an integrated AC power supply. This module operates at 50-60 Hz frequency. A ground connection is required for electromagnetic compliance (EMC) with the EMC directives in the European Union (EU) to earn the CE mark of conformity. The wire gauge of the protective earth is 14-12 AWG. The wire gauge of the functional earth is 14-10 AWG. A protective earth ground connection should be required for safety and regulatory compliance. Improper electrical wiring may cause damage to the communications connectors. Wiring failure in this module may result in electric shock.


The 2711P-K4M3A has an Ethernet port. Remember to use an Ethernet Category 5e Belden 7921A shielded cable according to the TIA 568-B.1 regulations, and use the RJ45 connectors according to the IEC 60603-7 regulations to meet the EU GHS emission limits and EMC Directive 89/336 / EEC.


Technical specifications:


ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711P-K4M3A
Product LinePanelview Plus 400
Display Size3.5 inch
Display ColorGrayscale
Input Type Keypad
CommunicationDH-485 Port
Input PowerAC
SoftwareFactoryTalk View ME
Memory64 MB
SeriesA, B, C, D, E
FirmwareVersion 3.20-5.10
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711P-K4M3A
Product LinePanelview Plus 400
Display Size3.5 inch
Display ColorGrayscale
Input Type Keypad
CommunicationDH-485 Port
Input PowerAC
SoftwareFactoryTalk View ME
Memory64 MB
SeriesA, B, C, D, E
FirmwareVersion 3.20-5.10
Type Lead Time Price Action
Repair Service 2-4 weeks $455cartAdd to Cart

Our highly skilled technicians can repair your 2711P-K4M3A. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Please refer to the manual for more information about the 2711P-K4M3A such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711P-K4M3A/-L1, Series -L1, Rev -L1 Request Quote
2711P-K4M3A/-L2, Series -L2, Rev -L2 Request Quote
2711P-K4M3A/-Rev A, Series -Rev A, Rev -Rev A Request Quote
2711P-K4M3A/-Rev B, Series -Rev B, Rev -Rev B Request Quote
2711P-K4M3A/-Rev C, Series -Rev C, Rev -Rev C Request Quote
2711P-K4M3A/-Rev D, Series -Rev D, Rev -Rev D Request Quote
2711P-K4M3A/-Rev E, Series -Rev E, Rev -Rev E Request Quote
2711P-K4M3A/-Rev F, Series -Rev F, Rev -Rev F Request Quote
2711P-K4M3A/-Rev G, Series -Rev G, Rev -Rev G Request Quote
2711P-K4M3A/-Rev H, Series -Rev H, Rev -Rev H Request Quote
2711P-K4M3A/-Rev I, Series -Rev I, Rev -Rev I Request Quote
2711P-K4M3A/-Rev J, Series -Rev J, Rev -Rev J Request Quote
2711P-K4M3A/-Rev K, Series -Rev K, Rev -Rev K Request Quote
2711P-K4M3A/-Rev L, Series -Rev L, Rev -Rev L Request Quote
2711P-K4M3A/- A, Series - A, Rev - A Request Quote
2711P-K4M3A/- B, Series - B, Rev - B Request Quote
2711P-K4M3A/- C, Series - C, Rev - C Request Quote
2711P-K4M3A/- D, Series - D, Rev - D Request Quote
2711P-K4M3A/- E, Series - E, Rev - E Request Quote
2711P-K4M3A/- F, Series - F, Rev - F Request Quote
2711P-K4M3A/- G, Series - G, Rev - G Request Quote
2711P-K4M3A/- H, Series - H, Rev - H Request Quote
2711P-K4M3A/- I, Series - I, Rev - I Request Quote
2711P-K4M3A/- J, Series - J, Rev - J Request Quote
2711P-K4M3A/- K, Series - K, Rev - K Request Quote
2711P-K4M3A/- L, Series - L, Rev - L Request Quote
2711P-K4M3A/A, Series A, Rev A Request Quote
2711P-K4M3A/B, Series B, Rev B Request Quote
2711P-K4M3A/C, Series C, Rev C Request Quote
2711P-K4M3A/D, Series D, Rev D Request Quote
2711P-K4M3A/E, Series E, Rev E Request Quote
2711P-K4M3A/F, Series F, Rev F Request Quote
2711P-K4M3A/G, Series G, Rev G Request Quote
2711P-K4M3A/H, Series H, Rev H Request Quote
2711P-K4M3A/I, Series I, Rev I Request Quote
2711P-K4M3A/J, Series J, Rev J Request Quote
2711P-K4M3A/K, Series K, Rev K Request Quote
2711P-K4M3A/L, Series L, Rev L Request Quote
2711P-K4M3A/M, Series M, Rev M Request Quote
Common misspellings:
  • 27l1P-K4M3A
  • 271lP-K4M3A
  • 2711P-KAM3A