Product image is representative; revision or series may vary. Contact us to request a specific version.
The FRS-R-4 fuse from Eaton Cutler-Hammer's Bussman series is engineered for reliable performance in electrical applications. With a current rating of 4 amperes, it is suitable for both AC and DC operations, handling up to 600VAC and 300VDC effectively.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Fuse |
| Product Line | Bussman |
| Part Number | FRS-R-4 |
| Weight | 0.13 lbs (0.06 kg) |
| Current Rating | 4A |
| Voltage Rating (AC) | 600 VAC |
| Voltage Rating (DC) | 300 VDC |
| Fuse Class | Class RK5 |
| AC Interrupting Rating | 200 kA RMS Symmetrical At 600 Volts AC |
| DC Interrupting Rating | 20 kA At 300 Volts DC |
| Response Type | Time-Delay |
| Time Delay | 10 Seconds Min. At 500% Rated Current |
| Element Type | Dual-Element |
| Connection Type | Ferrule End Connection × Ferrule End Connection |
| Fuse Indicator | Non-Indicating |
The Eaton Cutler-Hammer FRS-R-4 fuse is a compact yet robust protective device that weighs in at only 0.13 pounds. It possesses a 4A current rating and can operate securely under AC conditions up to 600 volts and DC conditions up to 300 volts, making it versatile across multiple setups. This fuse falls into the Class RK5 category, designed for general-purpose use while providing enhanced overload protection.
With an impressive AC interrupting rating of 200 kA RMS symmetrical at 600 volts, the FRS-R-4 is crafted to handle significant fault currents without compromising the integrity of the circuit. Additionally, it can manage a DC interrupting rating of 20 kA at 300 volts, enabling it to safeguard systems effectively under various electrical configurations.
The time-delay response of this fuse allows it to tolerate inrush currents, delivering a time delay of a minimum of 10 seconds when exposed to 500% of its rated current, which is crucial for maintaining circuit stability during transient conditions. Its dual-element construction adds an extra layer of reliability to its operation.
Connection of the FRS-R-4 is achieved through ferrule end fittings, ensuring straightforward installation without the need for complex modifications. It should be noted that this fuse is non-indicating, which means it does not provide a visual signal to indicate blown status, ensuring a clear understanding of when replacement is necessary.