Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
Eaton Cutler-Hammer S811+ Soft Starters S811+T24N3S

Product image is representative; revision or series may vary. Contact us to request a specific version.

S811+T24N3S

|

The S811+T24N3S is a solid-state soft starter from the Eaton Cutler-Hammer S811+ series. This unit is rated for a continuous current of 240 Amps, operating over a load voltage range of 200 to 575 Volts AC.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for S811+T24N3S

ManufacturerEaton Cutler-Hammer
Product TypeSolid-State Soft Starter
Product LineS811+ Soft Starters
Part NumberS811+T24N3S
UPC786685558981
Weight43.56 lbs (19.76 kg)
Continuous Current Rating240 Amps
Load Voltage Range200-575V AC
Control Voltage Supply24V DC
Horsepower Capacity60 Hp @ 200V, 75 Hp @ 230V, 150 Hp @ 460V
Ramp-Up Time15 Seconds
Duty Cycle4 Starts/Hour
Overcurrent Setting300% @ 40°C
PolesThree-Pole
Line Frequency47-63 Hz
User InterfaceLCD Digital Interface Module
Communication ProtocolModbus RTU
Frame Size200 mm T-Frame

The Eaton Cutler-Hammer S811+T24N3S functions as a solid-state soft starter, suitable for a variety of industrial applications. It has a substantial continuous current rating of 240 Amps, which allows for handling higher power demands. This device accommodates a load voltage spectrum ranging from 200 to 575 Volts AC.

The soft starter features a direct control voltage supply of 24V DC. Its ability to manage different power levels varies by voltage, with the capacity to handle 60 horsepower at 200V, 75 horsepower at 230V, and a maximum of 150 horsepower at 460V.

With a ramp-up time of 15 seconds, the S811+T24N3S provides smooth acceleration for connected loads. The unit is designed for a duty cycle of four starts per hour, ensuring it can handle frequent operational demands. An overcurrent setting is calibrated at 300% at 40°C to protect against higher fault currents.

This device operates within a line frequency of 47-63 Hz and employs a user-friendly LCD digital interface module, allowing users to easily monitor and control functions. For communication, the soft starter utilizes the Modbus RTU protocol, facilitating integration into broader automation systems. It comes in a 200 mm T-frame size, demonstrating a compact design suitable for various installations.