The Eaton Cutler-Hammer S811+T30N3S soft starter has been designed and manufactured as part of the S811+ product line for gently starting and stopping 3-phase induction motors. It has several useful features that include a digital interface module, a load output, a line input, a mounting base, DIP switches, and network terminals. The S811+T30N3S soft starter comes with a Size T frame and it can be installed on a panel or in an enclosure when it is connected to an enclosure. It can also operate in any orientation and it can operate at up to 15 g of operating shock and 3 g of operating vibration from any direction. The S811+T30N3S soft starter supports an operating temperature range from -40 to 122 degrees Fahrenheit and a storage temperature range from -58 to 158 degrees Fahrenheit.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for S811+T30N3S

ManufacturerEaton Cutler-Hammer
Product TypeSoft Starter
Product LineS811+ Soft Starters
Part NumberS811+T30N3S
UPC786685558998
Weight46.38 lbs (21.04 kg)
Frame SizeT-frame
Product SeriesS811+
Amperage Rating304 A
Maximum Current capacity526 A
CommunicationModbus RTU
Display MaterialLCD
Operating voltage200–600 V
Overload setting (frame)30–100% FLA
Trip class5, 10, 20, 30
Initial torque0–85%
Ramp time range0.5–180 seconds
Soft stop time range0–60 seconds
Kick-start time range0–2 seconds
Start / Stopping functionsKick start, Current Limit Start, Soft Stop and Pump Stop
Embedded I/OInputs: Stop (Permissive) / Start /Jog / Reset Outputs: One (1) Form A, Normally Open (N.O.) One (1) Form C contacts
Soft Starter TypeNon-combination
Amps304
OptionNo
Poles3
Volts AC240 max.
Volts DC120 max.
Insulating voltage Ui660V
Operating Frequency47-63 Hz
Bypass mechanical lifespan10M
Resistance to Shock15g

The Eaton Corporation S811+T30N3S soft starter is a 3-pole soft starter that is fully compatible with motors that have a voltage rating between 200 and 600 Volts AC. It is able to provide a current rating of 300 Amps and it controls the acceleration and deceleration of the motor. The Eaton Corporation S811+T30N3S 3-pole soft starter is a standard soft starter that provides a 15-second ramp with a 300% current limit at a maximum temperature of 40 degrees Celsius and it uses an inline connection. This starter can be mounted in almost any NEMA housing since its size has been reduced and streamlined. The Eaton Corporation S811+T30N3S does not come with any premium feature and it comes with a frame with a length of approximately 200 millimeters. This starter needs to be mounted in a place with good ventilation, and note that any nearby surface will start getting hot and this might be dangerous for the users working with and around the starter. It is important to maintain a room temperature between -30 and 70 degrees Celsius and to keep the equipment well ventilated in order to avoid overheating. There is a series of accessories such as mounting plates, power supplies, surge suppressors, and fans that are available to improve the overall performance of the Eaton Corporation S811+T30N3S 3-pole soft starter. These accessories are also available from the Eaton Corporation. This starter requires an additional power source of 24 Volts DC in order to function correctly.

The S811+T30N3S is a soft-starter device that is used with 3-Phase motors. This motor is capable of implementing starting and stopping options such as Kick start, Current Limit Start, Soft Stop and Pump Stop. This soft starter has a main supply voltage of 200-600 Volts AC and an assigned motor rating of 90 Kilowatts @ 230 Volts AC, 50 Hertz; 160 Kilowatts @ 400 Volts @ 50 Hertz; 200 Kilowatts @ 500 Volts, 50 Hertz; 100 Horsepower @ 200 Volts, 60 Hertz; 250 Horsepower @ 460 Volts AC @ 60 Hertz and 300 Horsepower @ 600 Volts AC @ 60 Hertz for standard, In-Line connection; 160 Kilowatts @ 230 Volts AC, 50 Hertz; 250 Kilowatts @ 400 Volts, 50 Hertz; 315 Kilowatts @ 500 Volts, 50 Hertz; 200 Horsepower @ 230 Volts, 60 Hertz; 450 Horsepower @ 480 Volts, 60 Hertz and 500 Horsepower @ 600 Volts, 60 Hertz assigned motor rating for Delta Connection.

The S811+T30N3S support comes with embedded I/O for wiring of external signals such as Stop (Permissive); Start, Jog and Reset. It is also equipped with one (1) Form A, Normally Open (N.O.) contact for bypass indication; one (1) Form C contacts used for device Ready (Normally Close) and Fault (Normally Open). An Emergency Stop button may also be wired across the 24 Volts DC terminals. For terminating signal wires, recommended minimum size of wire is 14 AWD or 2.5 mm2.

The S811+T30N3S delivers lowered maintenance costs, improved performance, increased reliability, prevents electrical penalty costs, prevents production losses from downtime, controls flexibility, simplifies product and component inventory, and helps meet and lowers utility requirements.