W250MLCNC
Operating at a frequency of 50 Hz, this reversing starter utilizes a solid-state, ambient compensated overload type for reliable performance. It allows manual, automatic, or remote reset options and f
The W200 Drives are Eaton Cutler-Hammer manufactured drives. They are non-reversing motor starter devices which are available in different sizes. They are 3-phase devices. These drives are cost-effective and efficient in nature. The W200 Series Drives come with built-in solid contacts. They have compact sizes and they need less space for installation. They offer robust performance and they are ideal replacement drives for old motor contactors and starters. They come with a lot of protection features, including integral overload protection features as Class 10, Class 20, or Class 30 overload relay. The W200 Drives are equipped with current sensing unitS that provide phase-loss protection, phase imbalance protection, and ground current sending protection. They feature low-voltage release. The drives take in input power from the motor supply circuits via control power transformers. The drives are available in different power ratings. These W200 Series Drives are mostly used in logistics machines, conveyor control machines, production machines, and different tooling machines.
The Eaton W200 Drives offer a lot of features in compact packages. They come with optional reversing e-stop capabilities and they are equipped with push-in terminals that provide protection against vibrations. The drives are equipped with LED indicators to show different trip conditions. They can also be replaced by remote reset and trip indicators. The W200 Drives are equipped with 8-pole switches for selecting the method of reset (manual or automatic). The drives are equipped with fault diagnostics features. They run for the entire operation process and alert the operators if they detect unusual activity in the system. Emergency stop buttons are also available on all the drive variants for stopping the drives faster bypassing the distributed opening sequences.
Browse available units in our catalog of W200 Drives.
Operating at a frequency of 50 Hz, this reversing starter utilizes a solid-state, ambient compensated overload type for reliable performance. It allows manual, automatic, or remote reset options and f
This magnetic motor starter operates under a rated frequency of 60 Hz and utilizes a coil voltage of 120 VAC. It includes three poles and is rated for an overload range of 4.0 to 20.0 A. The enclosure
The W210M2CFC has a current rating of 27 A at a frequency of 50 Hz and is suited for use within a frequency range of 50 to 60 Hz. Effective operational temperatures range from 0°C to 40°C, with a stor
This motor starter operates on three poles and features a coil voltage of 110 V with a frequency of 50 Hz. The device's vertical enclosure orientation is ideal for space-saving installations. It offer
This non-reversing starter functions effectively in horizontal or vertical mounting orientations, and is rated for 600 VAC. It operates within a frequency range of 50 Hz to 60 Hz, making it versatile
This NEMA size 4 contactor can handle up to 40 horsepower at 200 volts, 50 horsepower at 230 volts, and 100 horsepower at both 460 and 575 volts. It is rated for continuous currents up to 135 Amps and
This motor starter functions with three poles and is classified as a reversing starter. It operates in a vertical orientation and comes in a size 3 frame. Capable of handling separate control wiring,
This NEMA contactor features three poles and operates efficiently at a frequency of 50 Hz. Its design supports temperature ranges from 0°C to 40°C for operation and -30°C to 70°C for storage. It is co
This contactor operates on a coil voltage of 110 volts and is designed for 3-phase systems with a frequency of 50 Hz. It includes three poles and operates in ambient temperatures of up to 40°C. It can
This non-reversing starter is sized as NEMA Size 5, providing a horsepower rating of 75 at 200 V, climbing to 100 at 230 V. It holds a consistent rating of 200 HP when powered at either 460 V or 575 V