The CH250EPD circuit breaker from Eaton Cutler-Hammer is classified as a GFCI breaker, capable of providing essential ground fault protection. This breaker features a 50 A rated current and operates at a voltage range of 120/240 V. It's designed for single-phase configurations and includes two poles to support various applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | GFCI Circuit Breaker |
| Product Line | CH Loadcenters and Circuit Breakers |
| Part Number | CH250EPD |
| UPC | 782113912981 |
| Rated Current | 50 A |
| Number of Poles | 2 Poles |
| Voltage Rating | 120/240 V |
| Interrupting Capacity (kAIC) | 10 kAIC |
| Trip Type | Thermal-Magnetic |
| Frequency Rating | 50/60 Hz |
| Wire Range | #14–6 AWG Cu/Al |
| Terminal Type | Load Side Lug |
| Ground Fault Protection | Yes (GFCI) |
| Mounting Type | Plug-in (CH Loadcenter) |
| Phase Configuration | Single-Phase |
| Frame Type | CH Frame |
| Calibration | Fixed Thermal, Fixed Magnetic |
The Eaton Cutler-Hammer part number CH250EPD is a robust GFCI circuit breaker designed for safety and functionality. With a current rating of 50 A, it is suitable for applications requiring ground fault protection. This device operates with a voltage rating of 120/240 V and is intended for single-phase setups, making it highly versatile.
This circuit breaker is composed of two poles and has an interrupting capacity rated at 10 kAIC, allowing it to handle significant fault currents effectively. Equipped with a thermal-magnetic trip type, the CH250EPD reacts quickly to overloads and short circuits, safeguarding connected equipment.
It supports wire ranges from #14 to #6 AWG, suitable for both copper and aluminum conductors, enhancing its compatibility with different wiring configurations. The terminal type is a load side lug, which simplifies installation and maintenance.
This breaker is designed for a plug-in mounting type, specifically for use within CH Loadcenters, ensuring a seamless arrangement within electrical systems. Its fixed thermal and fixed magnetic calibration optimizes performance, ensuring reliable protection against ground fault occurrences in various applications.