CHB220
This circuit breaker consists of two poles and functions in a single-phase configuration. The CHB220 has a bolt-on connection type, allowing for robust attachment. Its screw/lug terminals can accommod
Eaton Cutler-Hammer's CH product line includes loadcenters, loadcenter accessories, circuit breakers, and specialty products. The CH loadcenters house branch circuit breakers and the wiring that distributes power to individual circuits in an electrical system. These loadcenters have copper busses that are silver flash-plated. CH circuit breakers can be single-pole or double-pole models, and several support quick-make and quick-break switch mechanisms. Plug-on neutral devices are also included in the CH series, and these neutral devices are used to simplify system wiring and elimiate pigtail connections. Some CH loadcenters can house high-AIC main breakers.
Browse available units in our catalog of CH Loadcenters and Circuit Breakers.
This circuit breaker consists of two poles and functions in a single-phase configuration. The CHB220 has a bolt-on connection type, allowing for robust attachment. Its screw/lug terminals can accommod
This circuit breaker features three poles and is specifically engineered for bolt-on mounting. It has an interrupting capacity of 10 kAIC at 240 VAC. The trip function utilizes fixed long-time and ins
This circuit breaker includes three poles, making it suitable for three-phase applications. It has an interrupt rating of 10 KAIC and accommodates wire sizes from #8 to #4 AWG. The operational tempera
This circuit breaker includes three poles and can handle wire sizes ranging from #14 to #8 AWG. It features an interrupt rating of 10 KAIC, ensuring reliable performance under fault conditions. This d
Incorporating a common breaker trip type and thermal-magnetic functions, the CH3090 features three poles. It offers an interrupt rating of 10 kAIC, ensuring reliability during overcurrent events. The
This circuit breaker is part of the CH series and features three poles, accommodating 3-phase systems. Its thermal-magnetic trip type provides both long-time and instantaneous trip functions, ensuring
Featuring a dual-pole configuration, the CH260EPD has an impressive short circuit rating of 10 kAIC. It supports wire sizes from #14 to #6 AWG copper and can be mounted via a plug-in style. The breake
This thermal magnetic circuit breaker consists of two poles, designed to manage long-time and instantaneous trips. Featuring a bolt-on connection type, its effective operation is guaranteed at a humid
This 2-pole circuit breaker operates effectively within a disrupting rating of 10 KAIC, ensuring reliable protection against electrical faults. The CHB290 utilizes a bolt-on connection system for simp