The CH3100ST from Eaton Cutler-Hammer is a robust molded case circuit breaker designed for three-phase applications. Rated at 100 amperes, this unit operates effectively at 240 volts AC and features a shunt trip for added safety.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for CH3100ST

ManufacturerEaton Cutler-Hammer
Product TypeMolded Case Circuit Breaker
Product LineCH Loadcenters and Circuit Breakers
Part NumberCH3100ST
UPC782113364353
Working Voltage240 Volts AC
System Phase3-Phase
Additional FeaturesEquipped with shunt trip
Rated Amperage100 Amperes
Number of Poles3 Poles
Rated Frequency50 to 60 Hertz
Interrupt Rating10 kiloamperes at 240 Volts AC
Connectable Conductor Cross-Sections10 to 1/10 American Wire Gauge (AWG)
Trip TypeCommon Breaker Trip
Actuator Design2-Position Handle
Enclosure RatingNEMA 3R
Mounting MethodPlug-On Mount
CompatibilityCH Frame Loadcenters

Eaton Cutler-Hammer's CH3100ST molded case circuit breaker is specifically designed for three-phase systems and rated for operation at up to 100 amperes. This breaker can handle a working voltage of 240 volts AC, making it suitable for a variety of electrical applications. Noteworthy is its 10 kiloampere interrupt rating, which enables it to effectively manage fault conditions.

This unit is constructed with three poles, and it works within a frequency range of 50 to 60 Hertz. The trip mechanism is a common breaker trip design, which ensures reliable disconnection during overload or short circuits. The 2-position handle design provides straightforward and user-friendly operation.

The CH3100ST can accommodate conductor sizes ranging from 10 to 1/10 AWG. It features a shunt trip functionality, which is useful for additional safety measures in specific applications. Its enclosure is rated NEMA 3R, offering protection against rain and snowfall, making it adaptable for both indoor and outdoor settings.

Installation is made easy with a plug-on mounting method, allowing for quick setup within compatible CH frame loadcenters. This combination of features makes the CH3100ST an ideal choice for managing power distribution in various environments.