Free UPS Ground on All Orders!
+1 (919) 205-4392
Eaton Cutler-Hammer CH Loadcenters and Circuit Breakers CHN220GF

Product image is representative; revision or series may vary. Contact us to request a specific version.

CHN220GF

|

The CHN220GF by Eaton Cutler-Hammer is a versatile GFCI circuit breaker exhibiting a rated current of 20 Amps and optimized for 120/240 volts AC applications. Designed for easy plug-in mounting, it is certified to UL 489 standards and provides essential ground fault protection.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for CHN220GF

ManufacturerEaton Cutler-Hammer
Product TypeGround Fault Circuit Interrupter (GFCI) Circuit Breaker
Product LineCH Loadcenters and Circuit Breakers
Part NumberCHN220GF
UPC786689217228
Number of Poles2 Poles
Rated Current20 A
Connection TypeLoad side and line side terminals
CertificationUL 489
Mounting TypePlug-in
Ground Fault Sensitivity5 mA
Frequency Rating50/60 Hz
Terminal TypeLug
Wire Range#14–6 AWG Cu/Al
Breaker Width3/4-inch per pole
Trip TypeCommon trip
Interrupting Capacity10 kAIC
Voltage Rating120/240 V AC

The Eaton Cutler-Hammer CHN220GF is a Ground Fault Circuit Interrupter (GFCI) circuit breaker that ensures protection against ground faults in electrical systems. Designed with a rated current of 20 A, this breaker operates effectively in 120/240 V AC environments. Its two-pole structure allows it to handle a range of applications while maintaining efficient power distribution.

The mounting method is plug-in, which simplifies installation. This device is especially suited for connections at both line and load terminals. With a high level of safety, it conforms to UL 489 certification standards. It incorporates a ground fault sensitivity level of 5 mA, which allows for quick detection and interruption in the event of a fault.

In addition, the CHN220GF comes equipped with a common trip type, allowing it to trip both poles simultaneously to enhance safety. The breaker can accommodate wire ranges from #14 to #6 AWG, whether using copper or aluminum conductors. Its lugs provide secure connections and ensure reliability during operation. The breaker occupies a width of 3/4-inch per pole and boasts an interrupting capacity of 10 kAIC, affirming its robustness in handling fault conditions. This makes the CHN220GF a reliable option for any electrical installation requiring ground fault protection.