D100EA20

Available Now
Request a Quote for D100EA20
Eaton Cutler-Hammer D100EA20 20 I/O Expander with 12 Inputs and 8 Outputs.
Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the D100EA20.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
Rated 4.6 with 12 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

D100EA20

Description: Eaton Cutler-Hammer D100EA20 20 I/O Expander with 12 Inputs and 8 Outputs.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the D100EA20.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.6 with 12 reviews

    Technical Specifications for D100EA20

ManufacturerEaton Cutler-Hammer
BrandEaton Cutler-Hammer
Part Number/Catalog No.D100EA20
Product Type20 I/O Expander
Power Supply115V AC
Inputs12
Input Type24V DC
Outputs8
Output TypeTriac
ManufacturerEaton Cutler-Hammer
BrandEaton Cutler-Hammer
Part Number/Catalog No.D100EA20
Product Type20 I/O Expander
Power Supply115V AC
Inputs12
Input Type24V DC
Outputs8
Output TypeTriac

About D100EA20

The D100EA20 is an expansion unit that is manufactured by the Cutler-Hammer brand. This 20 I/O expansion module has been designed with a 30-centimeter cable to function under a 115 Volt AC power supply. The expansion module has also been manufactured to have 24 Volt DC contacts, which are usually dry. The D100EA20 was primarily designed to provide additional outputs and inputs to the D100 PLC. The expansion unit is normally connected to the controller by way of cables. A controller can only accommodate a maximum of two expanding units, provided that the total number of inputs and outputs from the controller and the expander combined do not exceed the maximum I/O count listed for the controller.

The D100EA20 is not usually affected by the connection of an analog input module into the D100 controller since the analog input module is usually connected before the D100EA20. This only occurs when certain analog capabilities are required in the controller’s system. The D100EA20 expansion cables should be separated from any other cables, especially the power and input/output cables. Do not intertwine the expansion cables with the power and input/output cables. Always replace the connector covers after inserting the D100EA20’s cables. Note that the module’s expansion cables should not be disconnected or connected with the power on. Before applying power, make all connections and inspect them carefully. Remember to remove the power when detaching the expansion cables.

Repair Services for D100EA20

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your D100EA20. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Dimensions For D100EA20

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For D100EA20

Resolutions For D100EA20

Technical Specifications
ManufacturerEaton Cutler-Hammer
BrandEaton Cutler-Hammer
Part Number/Catalog No.D100EA20
Product Type20 I/O Expander
Power Supply115V AC
Inputs12
Input Type24V DC
Outputs8
Output TypeTriac
ManufacturerEaton Cutler-Hammer
BrandEaton Cutler-Hammer
Part Number/Catalog No.D100EA20
Product Type20 I/O Expander
Power Supply115V AC
Inputs12
Input Type24V DC
Outputs8
Output TypeTriac
About

The D100EA20 is an expansion unit that is manufactured by the Cutler-Hammer brand. This 20 I/O expansion module has been designed with a 30-centimeter cable to function under a 115 Volt AC power supply. The expansion module has also been manufactured to have 24 Volt DC contacts, which are usually dry. The D100EA20 was primarily designed to provide additional outputs and inputs to the D100 PLC. The expansion unit is normally connected to the controller by way of cables. A controller can only accommodate a maximum of two expanding units, provided that the total number of inputs and outputs from the controller and the expander combined do not exceed the maximum I/O count listed for the controller.

The D100EA20 is not usually affected by the connection of an analog input module into the D100 controller since the analog input module is usually connected before the D100EA20. This only occurs when certain analog capabilities are required in the controller’s system. The D100EA20 expansion cables should be separated from any other cables, especially the power and input/output cables. Do not intertwine the expansion cables with the power and input/output cables. Always replace the connector covers after inserting the D100EA20’s cables. Note that the module’s expansion cables should not be disconnected or connected with the power on. Before applying power, make all connections and inspect them carefully. Remember to remove the power when detaching the expansion cables.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your D100EA20. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your D100EA20. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

PDF