The Eaton Cutler-Hammer FAZ-C6/1-NA-SP is designed as a motor circuit breaker suitable for various applications. It features a single pole configuration and is rated for a current of 6A. This breaker operates at voltage ratings of 277 VAC and 48 VDC, with an interrupting capacity of 10 kAIc.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Motor Circuit Breaker |
| Product Line | FAZ Series |
| Part Number | FAZ-C6/1-NA-SP |
| Weight | 1.00 lbs (0.45 kg) |
| UPC | 0 15081636307 |
| Number of Poles | Single Poles |
| Rated Current | 6A |
| Voltage Rating (AC) | 277 VAC |
| Voltage Rating (DC) | 48 VDC |
| Minimum Frequency | 50 Hz |
| Maximum Frequency | 60 Hz |
| Interrupting Rating | 10 kAIc |
| Trip Curve | Curve C |
| Non-tripping Current | 1.13 × In for t > 1 hour |
| Mounting Method | DIN Rail Mount |
| Tightening Torque | 2.4 Nm |
Eaton Cutler-Hammer's FAZ-C6/1-NA-SP is an efficient motor circuit breaker that provides reliable protection for electric motors. This device accommodates a single pole configuration and supports a rated current of 6A, making it suitable for a variety of motor protection needs. With an AC voltage rating of 277 VAC and a DC rating of 48 VDC, this breaker is versatile for different types of electrical systems.
Frequency handling capabilities of this unit range from 50 Hz to a maximum of 60 Hz, covering typical operational standards. A robust interrupting rating of 10 kAIc provides confidence in its ability to manage fault conditions effectively. The trip curve is established as Curve C, which determines its operational response to overloads.
Additionally, the FAZ-C6/1-NA-SP allows non-tripping conditions at currents up to 1.13 times the nominal rating for durations exceeding one hour, offering flexibility in handling inrush currents. This motor circuit breaker is designed for straightforward installation with a DIN rail mounting method, ensuring stability during operation. Proper installation requires a tightening torque set at 2.4 Nm, reinforcing the connection within the system. For those needing a dependable circuit breaker in motor applications, the FAZ-C6/1-NA-SP represents an effective solution.