C0500E2AFB
Designed for varied voltage levels, the C0500E2AFB features primary voltage ratings of 220 x 400 volts, 230 x 460 volts, and 240 x 480 volts, while the secondary voltage outputs are at 110, 115, or 12
Eaton MTE transformers are control power transformers. They isolate control circuits from lighting and power circuits. They include epoxy-encapsulated coils and operate at 50/60 Hz frequency. MTE transformers have standard insulation rated for 130 degrees Celsius. They operate efficiently with copper magnet wire. Additionally, MTE transformers have terminals that are molded-in for durability. Some MTE transformers support secondary fuse clips, and all MTE transformers support optional primary fuse blocks with 2 poles that support rejection-type fuses. These transformers also feature silicon steel laminations. They are available with ratings from 50 to 1500 VA.
Browse available units in our catalog of MTE Transformers.
Designed for varied voltage levels, the C0500E2AFB features primary voltage ratings of 220 x 400 volts, 230 x 460 volts, and 240 x 480 volts, while the secondary voltage outputs are at 110, 115, or 12
This control transformer features a power rating of 500 VA with primary voltages of 220/440V, 230/460V, and 240/480V. Its secondary voltage options include 110V, 115V, and 120V. The transformer utiliz
The C0350E6UFB operates with primary voltages ranging from 208 to 600 volts and secondary voltages from 85 to 130 volts. The transformer functions effectively within a frequency range of 50 to 60 Hz a
Optimized for 1-phase applications, this transformer has selectable primary voltage ratings of 220/440V, 230/460V, and 240/480V. It provides secondary voltage options of 110V, 115V, and 120V, supporti
This transformer operates on multiple primary voltage levels, including 200, 220, and 440 VAC, as well as 208, 230, and 460 VAC, and 240 or 480 VAC. Its secondary voltage configurations include 23, 24
This unit functions effectively as a single-phase transformer, suitable for applications requiring a frequency between 50 Hz and 60 Hz. Constructed with copper magnet wire for the coil and high-grade
Operating within specified frequency ranges of 50 to 60 Hz, this transformer is configured as a single-phase device. It utilizes copper magnet wire for its winding material, which enhances its electri
This model operates efficiently across a minimum frequency of 50 Hz to a maximum frequency of 60 Hz. It is a single-phase unit made with copper winding material and utilizes molded-in screw terminals
This unit is a single-phase industrial control transformer with 100% copper windings and a maximum temperature rise of 55°C. It features molded-in screw terminals for easy connections and comes with a