Product image is representative; revision or series may vary. Contact us to request a specific version.
The Eaton Cutler-Hammer FDB3080 stands as a molded case circuit breaker with robust specifications. With three poles and rated at 80 amperes, it effectively accommodates various industrial applications where strong electrical management is crucial.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Series C Circuit Breakers |
| Part Number | FDB3080 |
| Weight | 4.00 lbs (1.81 kg) |
| UPC | 786679312537 |
| Amperage Rating | 80 Amperes |
| Poles | 3 Poles |
| Frame Type | F Frame |
| HACR Rated | Yes |
| Voltage Rating | 600 Volts AC, 250 Volts DC |
| Interrupt Rating | 18 kA at 240 Volts AC, 14 kA at 480 Volts AC, 14 kA at 600 Volts AC, 10 kA at 250 Volts DC |
| Connection | Load Side Lugs |
| Wire Size | 4-4/0 AWG |
| Frequency | 50/60 Hertz |
| Operating Temperature | -20 to 70 degrees Celsius |
| Certifications | UL |
The FDB3080 from Eaton Cutler-Hammer is a molded case circuit breaker engineered for dependable use in complex electrical systems. It operates at a rated amperage of 80 A and is designed with three poles to effectively manage electrical distribution. The frame type is categorized as F, allowing for appropriate application in various setups.
This device is HACR rated, indicating it is capable of handling heating, air conditioning, and refrigeration circuits. The voltage ratings reach up to 600 volts AC and 250 volts DC, making it versatile for different configurations. The unit offers multiple interrupt ratings, including 18 kA at 240 volts AC, 14 kA at both 480 and 600 volts AC, and 10 kA at 250 volts DC, ensuring it can handle significant fault currents.
Wiring connections are facilitated via load side lugs, which accommodate wire sizes ranging from 4 AWG to 4/0 AWG. Operating frequencies of 50 and 60 Hertz ensure compatibility with varied electrical environments. This circuit breaker is designed to function within a wide operational temperature range of -20 to 70 degrees Celsius. Additionally, it holds UL certification, reflecting compliance with established safety standards.