Free UPS Ground on All Orders!
+1 (919) 205-4392
Eaton Cutler-Hammer Series C Circuit Breakers GD3100

Product image is representative; revision or series may vary. Contact us to request a specific version.

GD3100

|

The GD3100 is a molded case circuit breaker from Eaton Cutler-Hammer's Series C line, providing robust protection for electrical circuits. Designed to handle a current rating of 100 A, it operates effectively at voltages up to 480 V AC.

Out of stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for GD3100

ManufacturerEaton Cutler-Hammer
Product TypeMolded Case Circuit Breaker
Product LineSeries C Circuit Breakers
Part NumberGD3100
Weight2.06 lbs (0.94 kg)
UPC786679072936
Rated Current100 A
Trip TypeT186
Frame SizeG Frame
Min. Frequency50 Hz
Max. Frequency60 Hz
Number of Poles3 Poles
Interrupt Rating at 240 V AC65 KAIC
Interrupt Rating at 480 VAC22 KAIC
Rated Voltage (AC)480 V AC
Rated Voltage (DC)125 to 250 V DC
Storage Humidity80% (non-condensing)
Operating Humidity80% (non-condensing)
Installation Altitude1000 MSL

The Eaton Cutler-Hammer GD3100 circuit breaker serves as a crucial component in electrical systems, particularly in industrial or commercial applications. Characterized as a molded case breaker, this device is well-rated for operating with a continuous current of 100 A. Its design accommodates a voltage rating of 480 V AC, while additionally supporting DC voltage ranging from 125 to 250 V. The GD3100 operates effectively across a frequency range of 50 to 60 Hz, which makes it adaptable for multiple environments.

This circuit breaker is configured with three poles, providing essential protection for three-phase electrical systems. The unit features a T186 trip type, ensuring it responds appropriately to overloads and fault conditions. The device is engineered to manage significant fault currents, offering an interrupt rating of 65 KAIC at 240 V AC and 22 KAIC at 480 V AC.

When considering installation conditions, the GD3100 can be utilized at altitudes up to 1000 MSL. This capacity makes it suitable for various locations. Both the operating and storage humidity specifications are set at 80% (non-condensing), enabling the breaker to perform reliably in environments with moderate humidity levels without moisture-related issues. The reliability and robustness of the GD3100 make it a reliable choice for ensuring the safety and integrity of electrical circuits.