The HND3800T36W circuit breaker from Eaton Cutler-Hammer's Series C is a molded case type designed for extensive applications. With a robust rated current of 800 A and a voltage capacity of 600 VAC, this device ensures reliable protection and performance in three-phase systems.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Series C Circuit Breakers |
| Part Number | HND3800T36W |
| Weight | 50.38 lbs (22.85 kg) |
| UPC | 786679264065 |
| Frame Type | NG-Frame |
| Rated Current | 800 A |
| Rated Voltage | 600 VAC |
| Minimum Frequency | 50 Hz |
| Maximum Frequency | 60 Hz |
| Number of Poles | 3 Poles |
| Phase Type | 3 Phase |
| Interrupting Capacity (AIC) at 240 VAC | 100 kAIC |
| Interrupting Capacity (AIC) at 480 VAC | 65 kAIC |
| Interrupting Capacity (AIC) at 600 VAC | 35 kAIC |
| Trip Functions | LSIG (Long-Time, Short-Time, Instantaneous, and Ground Fault) |
The Eaton Cutler-Hammer HND3800T36W model is categorized as a molded case circuit breaker, essential for protecting electrical circuits. Rated for an impressive 800 amperes, this device operates at a maximum voltage of 600 VAC, making it suitable for higher power applications. Built within an NG-Frame, its three-pole configuration is optimized for three-phase systems, ensuring efficient current management.
Designed to function within a frequency range of 50 Hz to 60 Hz, the device is equipped with notable interrupting capacities, making it versatile across different voltage levels. Specifically, it provides an interrupting capacity of up to 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC, effectively absorbing electrical surges and protecting connected equipment.
The trip function capabilities of the HND3800T36W are comprised of LSIG settings that allow for long-time, short-time, instantaneous, and ground fault tripping. This feature enhances safety in applications where varying current levels may be present. Overall, the features of this circuit breaker make it a reliable solution for a broad spectrum of electrical distribution needs, ensuring operational safety and performance.