Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
Eaton Cutler-Hammer Series C Circuit Breakers HND3800T36W

Product image is representative; revision or series may vary. Contact us to request a specific version.

HND3800T36W

|

The HND3800T36W circuit breaker from Eaton Cutler-Hammer's Series C is a molded case type designed for extensive applications. With a robust rated current of 800 A and a voltage capacity of 600 VAC, this device ensures reliable protection and performance in three-phase systems.

Out of stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for HND3800T36W

ManufacturerEaton Cutler-Hammer
Product TypeMolded Case Circuit Breaker
Product LineSeries C Circuit Breakers
Part NumberHND3800T36W
Weight50.38 lbs (22.85 kg)
UPC786679264065
Frame TypeNG-Frame
Rated Current800 A
Rated Voltage600 VAC
Minimum Frequency50 Hz
Maximum Frequency60 Hz
Number of Poles3 Poles
Phase Type3 Phase
Interrupting Capacity (AIC) at 240 VAC100 kAIC
Interrupting Capacity (AIC) at 480 VAC65 kAIC
Interrupting Capacity (AIC) at 600 VAC35 kAIC
Trip FunctionsLSIG (Long-Time, Short-Time, Instantaneous, and Ground Fault)

The Eaton Cutler-Hammer HND3800T36W model is categorized as a molded case circuit breaker, essential for protecting electrical circuits. Rated for an impressive 800 amperes, this device operates at a maximum voltage of 600 VAC, making it suitable for higher power applications. Built within an NG-Frame, its three-pole configuration is optimized for three-phase systems, ensuring efficient current management.

Designed to function within a frequency range of 50 Hz to 60 Hz, the device is equipped with notable interrupting capacities, making it versatile across different voltage levels. Specifically, it provides an interrupting capacity of up to 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC, effectively absorbing electrical surges and protecting connected equipment.

The trip function capabilities of the HND3800T36W are comprised of LSIG settings that allow for long-time, short-time, instantaneous, and ground fault tripping. This feature enhances safety in applications where varying current levels may be present. Overall, the features of this circuit breaker make it a reliable solution for a broad spectrum of electrical distribution needs, ensuring operational safety and performance.