Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
Eaton Cutler-Hammer Series C Circuit Breakers MT3700T

Product image is representative; revision or series may vary. Contact us to request a specific version.

MT3700T

|

The MT3700T part from Eaton Cutler-Hammer features a molded case breaker trip unit capable of handling a rated current of 700 A. Designed for efficiency, this unit operates within a voltage rating of 600 VAC across three poles, ensuring reliable performance in industrial settings.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for MT3700T

ManufacturerEaton Cutler-Hammer
Product TypeMolded Case Breaker Trip Unit
Product LineSeries C Circuit Breakers
Part NumberMT3700T
Weight4.00 lbs (1.81 kg)
UPC782114350140
Rated Current700 A
Number of Poles3 Poles
Voltage Rating600 VAC
Protection TypeThermal Magnetic
Trip FunctionsLI (Long-Time and Instantaneous)
Compatible Breaker FramesType MDL, HMDL, and HMDLDC
Minimum Operating Temperature-20°C
Maximum Operating Temperature60°C
Minimum Storage Temperature-60°C
Maximum Storage Temperature90°C

The MT3700T from Eaton Cutler-Hammer functions as a molded case breaker trip unit, engineered for optimal performance in industrial electrical environments. It supports a rated current of 700 Amperes while operating at a maximum voltage of 600 VAC, which is essential for maintaining circuit integrity in high-demand scenarios. Configured with three poles, this trip unit ensures thorough protection and control.

This device employs thermal magnetic protection, which allows it to respond effectively to overload conditions. The MT3700T also features trip functions categorized under LI, providing both long-time and instantaneous trip responses to prevent potential damage from electrical faults. It is compatible with various breaker frame types, including MDL, HMDL, and HMDLDC, enhancing its versatility within diverse systems.

In terms of environmental tolerance, this trip unit operates efficiently within a temperature range of -20°C to 60°C. Additionally, it can be stored in conditions ranging from -60°C to 90°C, ensuring stability and functionality across extreme conditions. Weighing in at 4 lbs, it presents a robust solution for reliable circuit protection and operation.