FD2070
Designed with fixed thermal and magnetic trip types, this breaker has an interrupting capacity of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. The load side features standard lug terminals for easy conn
Series C Circuit Breakers from Eaton Cutler-Hammer provide electrical protection to switchboards, panel boards, busway devices, and motor control centers. Trip units available in this series include electronic, thermal-magnetic, and magnetic-only trip units. Series C Circuit Breakers can support maximum system current ratings of 800A, maximum AC system voltage ratings of 600V AC, and maximum DC system voltage ratings of 250V DC. The contacts in these circuit breakers support high-speed "blow open" actions. Various external accessories are available for the Series C Circuit Breakers.
Browse available units in our catalog of Series C Circuit Breakers.
Designed with fixed thermal and magnetic trip types, this breaker has an interrupting capacity of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. The load side features standard lug terminals for easy conn
The FDB3045 offers 3 poles and manages voltages of 600 VAC AC and 250 VDC. It is engineered to provide significant interrupting capacities of 18 kAIC at 240 VAC and 14 kAIC at both 480 VAC and 600 VAC
This series C circuit breaker has a K-frame type and supports rated voltages of 600 VAC and 250 VDC. It includes three poles and delivers fixed thermal and fixed magnetic trip functions to ensure effe
This three-pole circuit breaker features a T186 trip type, with terminals configured for both line and load connections. The JDB3225 is rated for a frequency of 50 to 60 Hz and supports an interrupt r
This switch includes a three-pole configuration and is capable of interrupting currents of up to 40 kAIC at 415 VAC. Connection is facilitated via feed-thru with line and load side lugs included, maki
In the Series C line, the HFD2200 offers a robust solution with fixed thermal and magnetic trip options. This 2-pole breaker features an interrupting capacity of 100 kAIC at 240 VAC and 65 kAIC at 480
This circuit breaker features two poles and includes load-side standard pressure lugs for easy installation. Its interrupting capacities are notable, with ratings of 100 kAIC at 240 VAC, 65 kAIC at 48
This circuit breaker features three poles and employs fixed thermal and magnetic trip types. It provides impressive interrupting capacities of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC. Designed for
This circuit breaker, featuring three poles, operates effectively in a three-phase setting. It has a weight of 4.4 lbs and a voltage rating of up to 600 VAC for AC and 250 VDC for DC applications. The
With three poles, the EDS3175 is structured to function in three-phase configurations. It offers an interrupting rating of 42 kAIC at 240 VAC to ensure reliable performance during fault conditions. It