HJD3250W
The HJD3250W molded case circuit breaker operates efficiently in three-phase configurations with a maximum AC voltage of 600 VAC and a 250 VDC rating. This unit includes a trip unit designated as T186
Series C Circuit Breakers from Eaton Cutler-Hammer provide electrical protection to switchboards, panel boards, busway devices, and motor control centers. Trip units available in this series include electronic, thermal-magnetic, and magnetic-only trip units. Series C Circuit Breakers can support maximum system current ratings of 800A, maximum AC system voltage ratings of 600V AC, and maximum DC system voltage ratings of 250V DC. The contacts in these circuit breakers support high-speed "blow open" actions. Various external accessories are available for the Series C Circuit Breakers.
Browse available units in our catalog of Series C Circuit Breakers.
The HJD3250W molded case circuit breaker operates efficiently in three-phase configurations with a maximum AC voltage of 600 VAC and a 250 VDC rating. This unit includes a trip unit designated as T186
The circuit breaker is rated for 600 volts AC and 250 volts DC, with interrupt capacities of 100 kA at 240 volts AC, 65 kA at 480 volts AC, and 35 kA at 600 volts AC. Designed for adaptability, it has
This circuit breaker is designed as part of the Series C lineup and is classified under the KDB type with a frame size of K-Frame. The configuration is a complete breaker with three poles and a therma
This unit has a trip mechanism that employs both fixed thermal and fixed magnetic properties. It offers an interrupting capacity of 14 kAIC at 600 volts AC, ensuring it can handle substantial fault cu
This shunt trip kit is compatible with various frame types including J-Frame, JD, JDB, HJD, HJDDC, JDC, E2J, E2JM, and HMCP breakers. It can handle up to 250 A of rated current and is intended for rig
This circuit breaker features thermal-magnetic trip mechanisms and is designed for reliability under a range of conditions. The breaking capacity ratings under IEC 60947-2 are notable, with values var
This electronic circuit breaker operates with three poles and has a minimum frequency of 50 Hz and a maximum frequency of 60 Hz. The interrupt ratings are rated at 35 KAIC for 480 V AC and 65 KAIC for
This three-pole breaker is housed within a Frame G and features a trip type of T186. It can handle frequency ratings of both 50 and 60 Hz, and offers impressive interrupt ratings of 65 kAIC at 240 Vac
This circuit breaker is designed with a fixed thermal-magnetic trip style and includes three poles for 3-phase configurations. The interrupting capacity is rated at 65 kAIC for 240 V systems and 14 kA
This circuit breaker operates at 480Y/277 VAC for AC systems and 125/250 VDC for DC applications. It comprises three poles and features a fixed thermal and magnetic trip unit. Its interrupting capacit