This interlock features a sliding bar mechanism and is compatible with EG-frame circuit breakers. It operates effectively within temperature limits of -20 °C to 70 °C, and can be stored at temperature
Eaton Series G circuit breakers are molded case circuit breakers that support high-speed "blow-open" actions and have compact designs. Series G circuit breakers are available with electronic or thermal-magnetic trip units. They are also available with current ratings from 15 to 2500 Amps and voltage ratings of up to 690 Volts AC. Most Series G circuit breakers have 3 or 4 poles, and different breaker models are available with different neutral options. Some Series G circuit breakers support metric mounting hardware, and some support imperial mounting hardware. Earth leakage modules are also available in the Series G product line.
Browse available units in our catalog of Series G Circuit Breakers.
This interlock features a sliding bar mechanism and is compatible with EG-frame circuit breakers. It operates effectively within temperature limits of -20 °C to 70 °C, and can be stored at temperature
This circuit breaker plug-in adapter block supports operation in frequency ranges from 50 Hz to 60 Hz. It also works effectively within a temperature span of -20 °C to +55 °C and can be installed at a
This handle assembly is crafted for JG-Frame circuit breakers and complies with NEMA standards, including NEMA 1, NEMA 3R, and NEMA 12. It utilizes a through-the-door mounting method to ensure robust
This circuit breaker features two poles and utilizes thermal magnetic trip technology. It has a long-time and instantaneous trip function classified as LI. The interrupting capacity is rated at 100 kA
This unit features two poles and employs a combination of fixed thermal and fixed magnetic trip types. It has an interrupting capacity of 85 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 22 kAIC at 600Y/34
This circuit breaker features the NG-frame type and supports frequency ranges between 50 and 60 Hz. It incorporates trip functions including long-time, short-time, and ground fault protection. With an
The circuit breaker features a three-pole configuration, ideal for three-phase systems. It utilizes a fixed thermal trip mechanism combined with an adjustable magnetic trip, offering a customizable ap
This breaker contains three poles and is tailored for three-phase systems. It has a thermal-magnetic trip type, providing long-time and instantaneous responses to electrical faults. Additionally, the
This motor protection circuit breaker is designed to operate at 600 VAC and is rated for 250 A. The breaker type is JG, and it has a trip type of T186. With an interrupt rating of 65 kAIC at 480 VAC,
With a frame type classified as EG-Frame, the EGC3060FFG is well-suited for various electrical installations. It offers impressive interrupting ratings, achieving 200 kAIC at 240 VAC, 100 kAIC at 480