Product image is representative; revision or series may vary. Contact us to request a specific version.
The IC694MDL916 is a relay output module that is part of the PACSystem RX3i platform, currently under Emerson Automation, formerly produced by GE Intelligent Platforms (GE IP). This module has Sixteen (16) individually isolated Form A or Normally Open (N.O.) outputs. Each relay output is rated 0-125VDC (5/24/125 VDC nominal) and 0-250VAC (120-240VAC nominal) voltages with maximum current capacity of 4 Amperes.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | GE Fanuc Emerson |
|---|---|
| Product Line | RX3i PacSystem |
| Part Number | IC694MDL916 |
| Weight | 0.69 lbs (0.31 kg) |
| Series | PACSystem RX3i |
| Product Description | Relay Output module |
| No of Channels | Sixteen (16), individually isolated |
| Description | 16-Point Relay Output Modul |
| Output contact form | Form A (Normally Open, N.O.) |
| Operating Voltage | 0 to 125 Volts DC/ 5 to 250 Volts AC |
| Contact form | Normally Open (N.O.) Form A contacts |
| Output voltage range | 5-250VAC / 0-125 VDC |
| Switching current | 4.0 Amps |
| Nominal output voltage | 120-240 VAC; 5 / 24 / 125 VDC |
| I/O Capacity | 16 Isolated Form A Relay Outputs |
| Output voltage, nominal | 5/24/125 VDC; 120-240 VAC |
| Minimum Output current | 10 mA per point |
| Point to Point Isolation | Yes |
| Output current per channel | 10mA per point minimum; 4A for 5-250VAC maximum (resistive or general purpose); 4A for 5-30VDC maximum (resistive); 200mA for 125VDC (maximum resistive); 2A pilot duty per output (5 to 30VDC, 5 to 250VAC); 2A lamp load per output (5 to 30VDC, 5 to 250VAC |
| Maximum output current | 200mA for 125VDC (maximum resistive); 2A pilot duty per output (5 to 30VDC, 5 to 250VAC); 2A lamp load per output (5 to 30VDC, 5 to 250VAC); 4A for 5-30VDC maximum (resistive); 4A for 5-250VAC maximum (resistive or general purpose) loads |
| Max. Backplane Draw | 300 mill-Amps |
| Current draw | 300mA at 5VDC from backplane maximum (all outputs ON); 150mA at 24VDC from backplane relay power (all outputs ON) |
| Switching frequency | 20 cycles per minute maximum |
| Max. Response Time | 10 Milliseconds |
| Isolation, Field to Backplane (optical) and to Frame Ground | 250 VAC continuous; 1500 VAC for 1 minute |
| Relay contact life | 200,000 -1,000,000 operations |
| Terminal blocks | Box-style (IC694TBB032); Extended Box-style (IC694TBB132); Spring-style (IC694TBS032); Extended Spring-style (IC694TBS132) |
| External supply voltage | 5-250VAC / 0-125 VDC |
| Installation | RX3i PLC I/O Slots |
| Product Lifecycle Status | Active |
| Configuration | Proficy Machine Edition version 5.5 or the Service Pack 2 or later |
The IC694MDL916 is a Sixteen (16) channel Relay output module that belongs to the PACSystem RX3i product family. This module is a single-slot module that is formerly manufactured by GE Intelligent Platforms, now under Emerson Automation. It comes with individually isolated Form A or Normally Open (N.O.) contact outputs. The output contacts of this module are dry contacts, allowing any combination of AC and DC voltage to be conducted per channel. It supports conductions of 5-250VAC range with nominal values of 120-240 VAC along frequency range of 47-63 Hz. It is also compatible with 0-125 VDC voltage with nominal voltage levels of 5 / 24 / 125 VDC. Each output contact has minimum current capacity of 10 mA per point while the maximum ratings are 200mA for 125VDC (maximum resistive); 2A pilot duty per output (5 to 30VDC, 5 to 250VAC); 2A lamp load per output (5 to 30VDC, 5 to 250VAC); 4A for 5-30VDC maximum (resistive) and 4A for 5-250VAC maximum (resistive or general purpose) loads. The individual output channels are designed to a maximum of 20 cycles switching frequency per minute with relay contact life of 20000 operations at 5-250 VAC / 5-30 VDC when used with resistive (4 A), lamp or solenoid (2 A); 700000 operations when used with resistive (1 A), lamp or solenoid (0.5A) and 1,000,000 when used with resistive (0.1 A), lamp or solenoid (0.05 A); To further increase individual relay output contact protection, external snubber circuits may be applied. This module is functionally compatible with Proficy Machine Edition version 5.5, Service Pack 2 or later and PACSystems RX3i CPU Firmware version 3.81.
The GE Fanuc IC694MDL916 Relay Output Module is a 16-point relay output module for the RX3i PACSystems controller system. The IC694MDL916 Output Module has 16 Form A relay output points for controlling output loads, and each output point is completely isolated from the other. Each of the IC694MDL916 Output Module’s outputs has built-in noise immunity capability, and this module is suitable for a wide range of industrial output devices including, solenoids, motor starters, and indicators. The IC694MDL916 Output Module requires the use of either the spring-style IC694TBS032 terminal block, the box-style IC694TBB032 terminal block, or the extended spring-style/box-style IC694TBS132 of IC694TBB132 terminal blocks which offer additional shroud depth for accommodating shielded wires. The IC694MDL916 Output Module can generate and send reports such over-temperature and terminal block loss error messages, and it can be configured with the Proficy Machine Edition software version 5.5 or later or the Service Pack software version 2 or later. The GE Fanuc IC694MDL916 Output Module requires a 0 to 125 Volts DC/0 to 250 Volts AC rated external power supply for operation, and it has a backplane current rating of 300 milliamps 5 Volts DC. The IC694MDL916 Output Module has an output voltage range of 0 to 125 Volts DC/5 to 250 Volts AC at 47 to 63 Hertz and a lowest output load rating of 10 milliamps per point. The IC694MDL916 Output Module has a maximum output voltage drop of 0.3 Volts DC and a typical response time of 10 milliseconds (on/off). The IC694MDL916 Output Module has 16 individually isolated output channels with a common power output terminals per point. The IC694MDL916 Output Module comes with a back-panel DIP switch for selecting the module’s output default mode, and it also has LEDs for each individual output channel.
| Revision Part # | Also known as | |
|---|---|---|
| IC694MDL916AA | IC694MDL916-AA, Series AA, Rev AA | |
| IC694MDL916BA | IC694MDL916-BA, Series BA, Rev BA | |
| IC694MDL916CA | IC694MDL916-CA, Series CA, Rev CA | |
| Don't see your particular revision? Contact us now. | ||
Yes, the IC694MDL916 includes a free 2-year DO Supply warranty. You can upgrade to a 3-year warranty at checkout for even more protection.
The IC694MDL916 has Normally Open (N.O.) or Form A contact outputs.
The IC694MDL916 can be wired to voltage sources such as 0 - 125VDC and 0-250 VAC with nominal voltages of 5/24/125 VDC and 120 / 240 VAC.
Yes. Configurable output states are reset to On and Hold state. This is set via the DIP switch located on the back of the module.
No. External protection circuitry may be installed such as a snubber circuit.
The IC694MDL916 output contacts are Normally Open (N.O.) or Form A contact outputs.
The relay contact life of the IC694MDL916 ranges from 200000 to 1,000,000 operations.
The IC694MDL916 is a PACSystem RX3i Discrete output module formerly manufactured by GE Fanuc, now under Emerson Automation. This module features Sixteen (16) individually isolated Normally Open (N.O.) contacts. Each contact output can be operated with 0 - 125VDC with nominal voltages of 5/24/125 VDC; 0 - 250VAC at frequency of 47 to 63 Hz, with nominal input voltages of 120-240VAC. Each channel has rated output current of 10mA per point (minimum); 4A for 5-250VAC maximum for resistive or general purpose loads; 4A for 5-30VDC maximum for resistive loads; 200mA for 125VDC, maximum for resistive loads; 2A pilot duty output for 5 to 30VDC, 5 to 250VAC and 2A lamp load per output for 5 to 30VDC, 5 to 250VAC.