Description: The GE Fanuc IC200PWR102 module is an expanded power supply unit with extended functionalities from the Versamax series. It has an input voltage of 120 to 240 Volts AC with expanded 3.3 Volts DC voltage.
The GE Fanuc IC200PWR102 module is an expanded power supply unit with extended functionalities from the Versamax series. It has an input voltage of 120 to 240 Volts AC with expanded 3.3 Volts DC voltage.
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via DHL, UPS, Fedex, and TNT |
Repairs: | We offer repair service for the IC200PWR102. |
Exchange: | Exchange credit for your defective unit available. |
Brand | GE Fanuc |
Series | Versamax |
Part Number | IC200PWR102 |
Input Voltage | 120/240 Volts AC |
Output Voltage | 5 Volts DC and 3.3 Volts DC |
Extended Power | Yes |
Input Power | 27 Volts-Amps |
Holdup Time | 20 milliseconds |
Total Output Current | 1.5 Amperes Maximum |
Protection | Short circuit, overload |
Dimensions | 49 mm (1.93 in) x 133.4 mm (5.25 in) x 39 mm (1.54 in), not including the height of the carrier or the DIN-rail |
Brand | GE Fanuc |
Series | Versamax |
Part Number | IC200PWR102 |
Input Voltage | 120/240 Volts AC |
Output Voltage | 5 Volts DC and 3.3 Volts DC |
Extended Power | Yes |
Input Power | 27 Volts-Amps |
Holdup Time | 20 milliseconds |
Total Output Current | 1.5 Amperes Maximum |
Protection | Short circuit, overload |
Dimensions | 49 mm (1.93 in) x 133.4 mm (5.25 in) x 39 mm (1.54 in), not including the height of the carrier or the DIN-rail |
The GE Fanuc Versamax IC200PWR102 expanded power supply unit supplies power to devices that are connected to the backplane of PLC such as network interface units (NIUs), input and output units (I/O), and central processing units (CPUs). It uses AC power as the main power source unlike other types of modules from the Versamax series that use DC power. Although it serves as the primary power supply in the PLC, it can also be used as a secondary power supply when connected to a power supply booster carrier. The IC200PWR102 expanded power supply unit has an input voltage of 120 to 240 Volts AC and an output voltage of 5 Volts DC and 3.3 Volts DC. The module has an extended power feature, which means that the power can be expanded up to 3.3 Volts DC. It has an input power of 27 Volts-Amps and a holdup time of approximately 20 milliseconds.
The GE Fanuc Versamax IC200PWR102 expanded power supply module is safeguarded against short circuits and overloading. This module has a frequency range between 47 Hertz and 63 Hertz. If a jumper is present in the module, the input voltage may range between 85 and 132 Volts AC, although 120 Volts AC is the nominal voltage rating. If the jumper is absent, the input voltage may range between 176 and 264 Volts AC, and the nominal voltage is 240 Volts AC. The jumper operates safely with an input voltage of 120 Volts AC. However, it is recommended not to use a jumper with a 240 Volts AC input voltage rating because it may damage the IC200PWR102 module and it may be fatal to the users.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your IC200PWR102. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the IC200PWR102 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
IC200PWR102A |
IC200PWR102-A, Series A, Rev A | Request Quote |
IC200PWR102B |
IC200PWR102-B, Series B, Rev B | Request Quote |
IC200PWR102D |
IC200PWR102-D, Series D, Rev D | Request Quote |
IC200PWR102F |
IC200PWR102-F, Series F, Rev F | Request Quote |
IC200PWR102H |
IC200PWR102-H, Series H, Rev H | Request Quote |
IC200PWR102J |
IC200PWR102-J, Series J, Rev J | Request Quote |
IC200PWR102L |
IC200PWR102-L, Series L, Rev L | Request Quote |
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Brand | GE Fanuc |
Series | Versamax |
Part Number | IC200PWR102 |
Input Voltage | 120/240 Volts AC |
Output Voltage | 5 Volts DC and 3.3 Volts DC |
Extended Power | Yes |
Input Power | 27 Volts-Amps |
Holdup Time | 20 milliseconds |
Total Output Current | 1.5 Amperes Maximum |
Protection | Short circuit, overload |
Dimensions | 49 mm (1.93 in) x 133.4 mm (5.25 in) x 39 mm (1.54 in), not including the height of the carrier or the DIN-rail |
Brand | GE Fanuc |
Series | Versamax |
Part Number | IC200PWR102 |
Input Voltage | 120/240 Volts AC |
Output Voltage | 5 Volts DC and 3.3 Volts DC |
Extended Power | Yes |
Input Power | 27 Volts-Amps |
Holdup Time | 20 milliseconds |
Total Output Current | 1.5 Amperes Maximum |
Protection | Short circuit, overload |
Dimensions | 49 mm (1.93 in) x 133.4 mm (5.25 in) x 39 mm (1.54 in), not including the height of the carrier or the DIN-rail |
The GE Fanuc Versamax IC200PWR102 expanded power supply unit supplies power to devices that are connected to the backplane of PLC such as network interface units (NIUs), input and output units (I/O), and central processing units (CPUs). It uses AC power as the main power source unlike other types of modules from the Versamax series that use DC power. Although it serves as the primary power supply in the PLC, it can also be used as a secondary power supply when connected to a power supply booster carrier. The IC200PWR102 expanded power supply unit has an input voltage of 120 to 240 Volts AC and an output voltage of 5 Volts DC and 3.3 Volts DC. The module has an extended power feature, which means that the power can be expanded up to 3.3 Volts DC. It has an input power of 27 Volts-Amps and a holdup time of approximately 20 milliseconds.
The GE Fanuc Versamax IC200PWR102 expanded power supply module is safeguarded against short circuits and overloading. This module has a frequency range between 47 Hertz and 63 Hertz. If a jumper is present in the module, the input voltage may range between 85 and 132 Volts AC, although 120 Volts AC is the nominal voltage rating. If the jumper is absent, the input voltage may range between 176 and 264 Volts AC, and the nominal voltage is 240 Volts AC. The jumper operates safely with an input voltage of 120 Volts AC. However, it is recommended not to use a jumper with a 240 Volts AC input voltage rating because it may damage the IC200PWR102 module and it may be fatal to the users.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your IC200PWR102. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your IC200PWR102. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the IC200PWR102 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
IC200PWR102A |
IC200PWR102/A, Series A, Rev A | Request Quote |
IC200PWR102B |
IC200PWR102/B, Series B, Rev B | Request Quote |
IC200PWR102D |
IC200PWR102/D, Series D, Rev D | Request Quote |
IC200PWR102F |
IC200PWR102/F, Series F, Rev F | Request Quote |
IC200PWR102H |
IC200PWR102/H, Series H, Rev H | Request Quote |
IC200PWR102J |
IC200PWR102/J, Series J, Rev J | Request Quote |
IC200PWR102L |
IC200PWR102/L, Series L, Rev L | Request Quote |