Product image is representative; revision or series may vary. Contact us to request a specific version.
The S301-IRF-R514A model from Honeywell’s 301EM Series functions as a refrigerant gas sensor utilizing infrared (IR) technology. It is engineered to detect gas concentrations effectively, with a measurement range of 0-1000 ppm and a precision of 1 ppm, which makes it suitable for various monitoring applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Honeywell |
|---|---|
| Product Type | Refrigerant Gas Sensor |
| Product Line | 301EM Series |
| Part Number | S301-IRF-R514A |
| Sensing Technology | Infrared (IR) |
| Voltage Rating | 8.5 to 12.5 Vdc |
| Current Rating | 1 A at 10 Vdc, maximum |
| Measurement Range | 0-1000 ppm |
| Resolution | 1 ppm |
| Deadband | 20 ppm |
| Accuracy | ±10 ppm at 50 ppm / ±40 ppm at 500 ppm |
| Response Time (T90) | 60 seconds |
| Warm-Up Time | 15 minutes |
| Operating Temperature Range | 0°C to 40°C |
| Humidity Range | 0 to 95% RH (Non-Condensing) |
| Enclosure Material | ABS - Polycarbonate |
| Calibrated Gas | R514A |
The Honeywell S301-IRF-R514A, part of the 301EM Series, is recognized as a reliable infrared (IR) refrigerant gas sensor. Weighing 2.33 lbs, it has a voltage operational range of 8.5 to 12.5 Vdc, allowing for flexible integration into various systems. The device can manage a maximum current rating of 1 A at 10 Vdc, ensuring efficient performance for monitoring tasks.
It detects refrigerant gases within a specified measurement range of 0 to 1000 ppm, with a resolution capability of 1 ppm. The sensor exhibits a deadband of 20 ppm, allowing it to maintain sensitivity without frequent false triggers. Its accuracy levels are notably ±10 ppm at 50 ppm and ±40 ppm at 500 ppm, proving beneficial for precise environmental assessments.
In terms of response, the sensor achieves a T90 of 60 seconds, meaning it can react adequately to changes in gas concentration after this interval. Additionally, a warm-up time of 15 minutes is required for proper calibration before usage.
The operating conditions for the S301-IRF-R514A are quite accommodating, supporting temperatures from 0°C to 40°C and relative humidity levels between 0% to 95% RH in a non-condensing environment. It is constructed from ABS polycarbonate material and is calibrated specifically for R514A gas, ensuring consistent reliability in its applications.