The RM7896C1010 from Honeywell's 7800 Series functions as a microprocessor-controlled on-off primary controller. It operates at a voltage rating of 120 VAC with a frequency of 50/60 Hz, allowing for effective control in various heating applications.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for RM7896C1010

ManufacturerHoneywell
Product TypeMicroprocessor-based integrated on-off primary control
Product Line7800 Series
Part NumberRM7896C1010
Main Flame Establishing Period10 seconds
Voltage Rating120 VAC
Input Voltage Frequency50/60 Hz
Minimum Operating Temperature-40°C
Maximum Operating Temperature60°C
Pilot TypeInterrupted
Postpurge Timing15 seconds
Humidity Range85% RH (non-condensing)
Power Dissipation10 W maximum
Maximum Total Connected Load2000 VA
Fusing15A Fast-Blow, Type SC or equivalent
Mounting TypePlug-in module on Q7800A/Q7800B wiring subbase
Pilot Flame Establishing Period4 or 10 seconds

The RM7896C1010 part number represents a highly efficient microprocessor-based integrated on-off primary control system from Honeywell’s 7800 Series. It runs on a nominal voltage of 120 VAC and can handle frequencies of 50 or 60 Hz. This particular control unit is tailored for a diverse range of heating applications that require precise flame control.

In terms of temperature endurance, the RM7896C1010 is rated to perform optimally between -40°C and 60°C, ensuring reliability in extreme environments. Additionally, it is capable of functioning in humidity levels reaching up to 85% relative humidity without condensation. Power dissipation remains within a limit of 10 watts to ensure efficient operation.

For operational safety, the device's maximum total connected load is rated at 2000 VA, and it employs a 15A fast-blow fuse of Type SC or an equivalent specification for protection. The main flame establishing period is set at 10 seconds, while the pilot flame can establish within either 4 or 10 seconds depending on configuration. The postpurge timing is designed to last for 15 seconds, ensuring the system operates smoothly during and after usage.

Installation is made convenient through its plug-in module, which can be mounted on the Q7800A or Q7800B wiring subbases. Overall, the RM7896C1010 offers robust features that cater to both efficiency and safety standards in a variety of controlled heat applications.