Product image is representative; revision or series may vary. Contact us to request a specific version.
The Honeywell KS84621440 serves as a burner control unit within the IFD Series. It operates on a voltage of 120 VAC and is designed for input frequencies of either 50 or 60 Hz, making it versatile for various applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Honeywell |
|---|---|
| Product Type | Burner Control Unit |
| Product Line | IFD Series |
| Part Number | KS84621440 |
| Voltage Rating | 120 VAC |
| Input Voltage Frequency | 50/60 Hz |
| IP Rating | IP 54 |
| Operating Temperature Range | -20°C to 60°C |
| Mounting Type | DIN rail or M5 screw mounting |
| Safety Time During Operation (tSB) | 2 s |
| Ignition Time (tZ) | Approx. 3 s |
| Valve Output Current | 1 A max. |
| Ignition Output Current | 2 Amps max., cos φ = 0.2 |
| Signalling Contact Rating | 2 Amps, 253 VAC |
Part number KS84621440 from Honeywell belongs to the IFD Series and functions as a burner control unit. This device is engineered to operate with a voltage rating of 120 VAC and supports input frequencies of 50/60 Hz, providing adaptability for various systems. With a weight of only 1.34 lbs, it is designed for easy installation, accommodating either DIN rail or M5 screw mounting for flexible placement options.
The control unit has a specified IP54 rating, ensuring it is protected against dust particles and water splashes, making it suitable for a wide range of environmental conditions. It is capable of functioning within an operating temperature range from -20°C to 60°C, ensuring performance stability even in less-than-ideal conditions.
In terms of performance metrics, the KS84621440 has a safety operational time (tSB) of 2 seconds and an ignition time (tZ) of approximately 3 seconds, allowing for efficient startup of burner operations. The output current specifications include a maximum of 1 A for valve output and 2 A for ignition output at a power factor (cos φ) of 0.2, providing robust control capabilities. Moreover, the signaling contact rating reaches up to 2 Amps at 253 VAC, which reinforces the operational reliability of this burner control unit.