KS84621440

|

The Honeywell KS84621440 serves as a burner control unit within the IFD Series. It operates on a voltage of 120 VAC and is designed for input frequencies of either 50 or 60 Hz, making it versatile for various applications.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for KS84621440

ManufacturerHoneywell
Product TypeBurner Control Unit
Product LineIFD Series
Part NumberKS84621440
Voltage Rating120 VAC
Input Voltage Frequency50/60 Hz
IP RatingIP 54
Operating Temperature Range-20°C to 60°C
Mounting TypeDIN rail or M5 screw mounting
Safety Time During Operation (tSB)2 s
Ignition Time (tZ)Approx. 3 s
Valve Output Current1 A max.
Ignition Output Current2 Amps max., cos φ = 0.2
Signalling Contact Rating2 Amps, 253 VAC

Part number KS84621440 from Honeywell belongs to the IFD Series and functions as a burner control unit. This device is engineered to operate with a voltage rating of 120 VAC and supports input frequencies of 50/60 Hz, providing adaptability for various systems. With a weight of only 1.34 lbs, it is designed for easy installation, accommodating either DIN rail or M5 screw mounting for flexible placement options.

The control unit has a specified IP54 rating, ensuring it is protected against dust particles and water splashes, making it suitable for a wide range of environmental conditions. It is capable of functioning within an operating temperature range from -20°C to 60°C, ensuring performance stability even in less-than-ideal conditions.

In terms of performance metrics, the KS84621440 has a safety operational time (tSB) of 2 seconds and an ignition time (tZ) of approximately 3 seconds, allowing for efficient startup of burner operations. The output current specifications include a maximum of 1 A for valve output and 2 A for ignition output at a power factor (cos φ) of 0.2, providing robust control capabilities. Moreover, the signaling contact rating reaches up to 2 Amps at 253 VAC, which reinforces the operational reliability of this burner control unit.