| Manufacturer | Honeywell |
|---|---|
| Product Type | Load Cell |
| Product Line | Other |
| Part Number | 060-9613-01-02 |
| Voltage Rating | Excitation of up to 15 Volts DC or AC; 10 Volts DC calibration voltage |
| Operating Temperature Range | -54°C to 121°C |
| Compensated Temperature Range | 15°C to 71°C |
| Housing Material | 17-4 PH stainless steel (for capacities below 200,000 lbs) |
| Output | 2-3 mV/V (standard and unamplified, varies by capacity) |
| Bridge Resistance | 350 Ω (nominal) |
| Non-linearity | ±0.1 to ±0.2% Full Scale (capacity-dependent) |
| Hysteresis | ±0.08 to ±0.1% Full Scale (capacity-dependent) |
| Insulation Resistance | 5000 MΩ at 50 VDC |
| Load Range (Series) | 5 to 500,000 lbs |
| Operation | Compression only |
| Maximum Allowable Load | 150% of full scale |
The 060-9613-01-02 load cell from Honeywell delivers high precision and reliability in load measurement tasks. It is capable of functioning with an excitation voltage up to 15 Volts, and is calibrated using a 10 Volts DC input, making it versatile across different applications where varying power sources may be used.
Extending its operational capabilities, the unit maintains performance in extreme temperatures, with a wide operating range from -54°C to 121°C. For compensating temperature influences, a range between 15°C to 71°C is established to enhance measurement accuracy.
This load cell is constructed with a durable 17-4 PH stainless steel housing for models handling capacities below 200,000 lbs, ensuring longevity in demanding conditions. The output specification varies based on the load cell’s capacity, typically producing a standard output of 2-3 mV/V in an unamplified state.
In addition to featuring a nominal bridge resistance of 350 Ω, this load cell exhibits non-linearity within ±0.1 to ±0.2% of the full scale, which is dependent on its rated capacity. Hysteresis affects readings minimally, typically resting between ±0.08 to ±0.1% of full scale, also capacity-dependent. Insulation resistance is rated at an impressive 5000 MΩ at 50 VDC, implying effective protection against electrical faults.
The load range of the Honeywell load cell spans from 5 lbs to 500,000 lbs, providing versatility for various applications. It is specifically designed for compression operations only, with the capacity to endure loads up to 150% beyond its rated full scale without compromising accuracy or integrity.