Product image is representative; revision or series may vary. Contact us to request a specific version.
The Honeywell C7355B1052 is designed as an in-duct air quality monitor. This device measures various environmental parameters including particulate matter, CO2 levels, temperature, and humidity.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Honeywell |
|---|---|
| Product Type | In-Duct IAQ Monitor |
| Product Line | Other |
| Part Number | C7355B1052 |
| Monitored Parameters | PM2.5, PM10, Carbon Dioxide, TVOC, Temperature, and Relative Humidity |
| AC Input Power Voltage | 18 to 27 VAC |
| DC Input Power Voltage | 12 to 28 VDC |
| Minimum Frequency | 50 Hz |
| Maximum Frequency | 60 Hz |
| Maximum Power Consumption | 3 W |
| Baud Rate Range | 4800 to 115200 bps |
| Applicable Duct Air Speed | 6.56 to 32.8 ft/s |
| CO2 Measurement Range | 0 to 5,000 ppm |
| Particulate (PM2.5/PM10) Range | 0 to 1,000 μg/m³ |
| Temperature Sensing Range | -20 °C to 60 °C |
| Humidity Sensing Range | 0% to 100% RH (Non-Condensing) |
Honeywell's C7355B1052 in-duct air quality monitor provides essential data regarding indoor air quality. This device's capability extends to monitoring multiple parameters, such as PM2.5 and PM10 particulate levels, carbon dioxide concentrations, TVOC levels, temperature, and humidity. Weighing in at 1.87 lbs, it establishes a lightweight profile that facilitates installation in various ductwork configurations.
It operates on alternating current (AC) voltage between 18 and 27 VAC or at direct current (DC) levels of 12 to 28 VDC. Engineered for reliability, it operates within a frequency range of 50 Hz to 60 Hz and maintains low power requirements with a maximum consumption of just 3 watts. Communication capabilities are proficient, with a baud rate that adjusts between 4800 and 115200 bps for effective data transmission.
Designed to function optimally in duct air at velocities of 6.56 ft/s to 32.8 ft/s, it accurately measures carbon dioxide within a range of 0 to 5,000 ppm, ensuring critical monitoring of this significant greenhouse gas. For particulate measurements, PM2.5 and PM10 levels can be tracked from 0 to 1,000 μg/m³, contributing vital information to assess air quality.
In terms of temperature sensing, the monitor has a range from -20 °C to 60 °C, while the humidity sensing capabilities extend from 0% to 100% relative humidity, ensuring precise control of environmental conditions without condensation interference. This in-duct IAQ monitor is an integral component for maintaining air quality in HVAC systems.