Product image is representative; revision or series may vary. Contact us to request a specific version.
The FX2N-2LC is a temperature control block from Mitsubishi's FX series. This unit utilizes PID, PI, and two-position control methods to manage temperature operations effectively. It supports various thermocouples, such as K, J, R, and S, along with Pt100 inputs.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Mitsubishi |
|---|---|
| Product Type | Temperature Control Block |
| Product Line | FX Series |
| Part Number | FX2N-2LC |
| Weight | 0.94 lbs (0.43 kg) |
| Control Method | PID, PI, and Two-position control |
| Input Type | Thermocouple (K, J, R, S, etc.), Pt100 |
| Input Points | 2 (Temperature and Current) |
| Output Points | 2 (NPN open collector) |
| Temperature Setting Range | Matches input sensor range |
| Measurement Precision | ±0.7% of span ± 1 digit |
| Control Period | 500 ms |
| Power Supply Requirements | 24 VDC (-15% to +10%) |
| Current Consumption | 24 VDC, 55 mA; 5 VDC, 70 mA |
| Operating Temperature Range | 0°C to 55°C |
| Storage Temperature Range | -20°C to 75°C |
| Sampling Period | 500 ms (Temperature); 1s (Current) |
| Heater Disconnection Detection | 0.0 to 100.0 A |
| Status Indication | LEDs for power, 24V supply, OUT1, OUT2 |
The Mitsubishi FX2N-2LC is a temperature control block for applications requiring precise temperature management. Control strategies implemented include PID, PI, and two-position control formats. Multiple input types are accommodated, including thermocouples (K, J, R, S, among others) and Pt100 sensors, offering versatility in temperature monitoring.
This model features two input points dedicated to measuring temperature and current and two output points configured as NPN open collectors. The temperature setting range is tailored to match the input sensor specifications, ensuring accurate operation across various environments. With a measurement accuracy of ±0.7% of span ± 1 digit, it provides reliable data for critical processes.
The adjustment control period is set at 500 ms, facilitating prompt responses to temperature fluctuations. It requires a power supply of 24 VDC with a tolerance of -15% to +10%. Current consumption is rated at 55 mA when utilizing 24 VDC and 70 mA when using 5 VDC.
The operational temperature span is 0°C to 55°C, while the storage capabilities allow for temperatures ranging from -20°C to 75°C. The unit samples temperatures every 500 ms, with a one-second interval for current measurements. Heater disconnection detection operates within a range of 0.0 to 100.0 A to enhance reliability. Status indicators, including LEDs for power, 24V power supply, and outputs OUT1 and OUT2, provide visual confirmation of the unit's operation.