Free UPS Ground on All Orders!
+1 (919) 205-4392
Omron 3G2 3G2A5-OC224

Product image is representative; revision or series may vary. Contact us to request a specific version.

3G2A5-OC224

|

The Omron 3G2A5-OC224 is a contact output unit capable of supporting 32 points. It includes 4 circuits and has a maximum internal current consumption of 200 mA at 5 VDC.

Out of stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 3G2A5-OC224

ManufacturerOmron
Product TypeContact Output Unit
Product Line3G2
Part Number3G2A5-OC224
Weight1.19 lbs (0.54 kg)
Number of Points32 points (8 points/common, 4 circuits)
Internal Current Consumption200 mA at 5 VDC max
BitG6B-114P-FD-US-M (24 VDC) w/socket
Max Switching Capacity2 A at 250 VAC, 0.5 A at 250 VAC, 2 A at 24 VDC (8 A/common, 32 A/unit)
Min Switching Capacity10 mA at 5 VDC
Power Supply Voltage24 VDC ±10%
Power Supply Current10 mA/point, 320 mA/unit
Relay Life (Electrical)300,000 ops (resistive), 100,000 ops (inductive)
Relay Life (Mechanical)50,000,000 ops
ON Response Time15 ms max
OFF Response Time15 ms max

The 3G2A5-OC224 contact output unit provided by Omron is an effective solution for discrete output applications. This unit has 32 output points arranged in 4 circuits, with 8 points sharing each common configuration. The module measures a maximum weight of 600 grams and utilizes a bit type G6B-114P-FD-US-M configured for 24 VDC.

It has an internal current consumption rate capped at 200 mA at 5 VDC. This unit is designed for a mains voltage supply of 24 VDC, with an allowable tolerance of ±10%. For operation, the power supply current is set at 10 mA per point, aggregating to 320 mA for the entire unit. The switching capabilities of this output unit are particularly notable; it can manage a maximum switching capacity of 2 A at 250 VAC and 2 A at 24 VDC, with a notable peak at 8 A per common and 32 A across the complete unit. Conversely, the applicable minimum switching capacity is measured at 10 mA for 5 VDC.

The unit's relay life is considerable, featuring an expected lifespan of 300,000 operations when used with resistive loads and up to 100,000 operations for inductive loads. The mechanical lifespan, however, extends significantly further to 50 million operations. Response times for both ON and OFF states are limited to a maximum of 15 milliseconds, ensuring the unit's efficiency during operation.