C500-NC211

|

The C500-NC211 is a position control unit from Omron’s C500 series, specifically designed for precision in two-axis control applications. Its lightweight design weighs just 0.7 kg, making it suitable for integration into various systems.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for C500-NC211

ManufacturerOmron
Product LineC500
Part NumberC500-NC211
Weight0.88 lbs (0.40 kg)
NamePosition Control Units
Mass0.7 kg
Number of Controlled AxesTwo-axis
Interpolation FunctionAvailable (linear interpolation)
Maximum Switching Capacity30 mA at 5 to 24 VDC
Minimum Switching Capacity7 mA at 5 to 24 VDC
Leakage Current0.1 mA max.
Residual Voltage0.6V max.
External Power Supply24 VDC (max 50 mA)
Input Voltage12 to 24 VDC
Input Current5 mA (at 12V); 15 mA (at 24V)
ON Voltage10.5 VDC min.
OFF Voltage3.0 VDC
ON Response Time1 ms max.
OFF Response Time1 ms max.

Omron's C500-NC211 position control unit is engineered for two-axis control tasks. This device weighs 0.7 kg, allowing for simple installation in diverse applications. The unit features linear interpolation capabilities, enhancing its functionality in complex positional adjustments.

For its operational parameters, this control unit achieves a maximum switching capacity of 30 mA and a minimum capacity of 7 mA, both effective within the input range of 5 to 24 VDC. It effectively minimizes leakage current, maintaining it at a maximum of 0.1 mA while ensuring a maximum residual voltage of 0.6V.

The C500-NC211 requires an external power supply of 24 VDC with an available draw of up to 50 mA, and it is compatible with input voltages spanning from 12 to 24 VDC. Input current consumption is rated at 5 mA when operating at 12V and 15 mA at 24V. For operational integrity, the ON voltage should reach a minimum of 10.5 VDC, with an OFF voltage mark of 3.0 VDC.

The device's response times are efficient, with both ON and OFF conditions achieved within 1 ms maximum. This quick response ensures rapid position adjustments, making the C500-NC211 an excellent choice for applications demanding precise control.