The C500-OA223 TRIAC output unit from Omron combines compact design with reliability. With a weight of 0.6 kg and a C-shape form factor, this unit reinforces a practical solution for various applications.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for C500-OA223

ManufacturerOmron
Product LineC500
Part NumberC500-OA223
Weight1.44 lbs (0.65 kg)
DescriptionTRIAC Output Unit
Max. Switching Capacity1 A, 250 VAC, 50/60 Hz (4 A/common, 5 A/Unit)
Min. Switching Capacity10 mA (resistive load), 40 mA (inductive load), 10 VAC
Leakage Current3 mA (100 VAC) max., 6 mA (200 VAC) max.
Residual Voltage1.2 V max
ON Response Time1 ms max
OFF Response TimeHalf of load frequency max
Number of Points24 (8 points/common, 3 circuits)
Internal Current Consumption450 mA, 5 VDC max.
Fuse Capacity5 A, 250 V (two fuses)

Omron's C500-OA223 is engineered as a TRIAC output unit, specifically designed to fulfill the needs of automation tasks. The dimensions of this unit exhibit a C-shape, making it suitable for various panel layouts. Weighing in at 0.6 kg, it provides portability without sacrificing performance.

This unit is capable of handling a maximum switching capacity of 1 A at 250 VAC, accommodating both 50 Hz and 60 Hz frequencies, with a broader rating of 4 A per common terminal and 5 A per unit. It also supports minimal switching capacities with a threshold as low as 10 mA for resistive loads and up to 40 mA for inductive applications, making it versatile in its usage.

Leakage current remains low, capped at 3 mA maximum for 100 VAC systems and 6 mA for 200 VAC arrangements. Furthermore, the residual voltage is maintained at a maximum of 1.2 V, ensuring efficient operation during active states. The device offers impressive response times; the ON response time is labeled as 1 ms or less, while the OFF response time is limited to a maximum of half the load frequency.

For functional capacity, it features a total of 24 points configured as 8 points per common with the arrangement of three circuits. The unit's internal current consumption is limited to 450 mA with a power supply of 5 VDC. To protect against overloads, it includes two fuses with a rating of 5 A at 250 V, ensuring durable operation under various conditions.