Free UPS Ground on All Orders!
+1 (919) 205-4392
Omron C500 C500-OA226

Product image is representative; revision or series may vary. Contact us to request a specific version.

C500-OA226

|

The Omron C500-OA226 represents a TRIAC output unit. This module is designed with a maximum internal current consumption of 450 mA at 5 VDC. It features a dual fuse capacity of 5 A at 250 V, with each fuse measuring 6.35 mm in diameter and 32 mm in length.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for C500-OA226

ManufacturerOmron
Product LineC500
Part NumberC500-OA226
Weight1.00 lbs (0.45 kg)
Name of ModuleTRIAC Output Unit
Internal Current Consumption450 mA, 5 VDC max
Fuse Capacity5 A, 250 V; 6.35 mm dia. x 32 mm (two fuses)
Max. Switching Capacity1.2 A, 250 VAC, 50/60 Hz (4 A/common, 5 A/unit)
Min. Switching Capacity100 mA at 10 VAC, 50 mA at 24 VAC, 10 mA at 100 VAC, 10 mA at 240 VAC
Leakage Current1.5 mA (120 VAC, 60 Hz) max, 3.0 mA (240 VAC, 60 Hz) max
Residual Voltage1.5 VAC max. for 100 to 600 mA, 1.5 VAC for 50 to 100 mA, 5.0 VAC for 10 to 50 mA
ON Response Time1 ms max
OFF Response Time1/2 of load frequency + 1 ms max
No. of Points16 (8 points/common, 2 circuits)

Omron’s C500-OA226 is noted for its implementation as a TRIAC output unit, constructed with careful attention to its specifications and operational efficiencies. The module's weight is a manageable 0.6 kg. It has a distinctive C-shape design, allowing for convenient integration in control applications. With a maximum internal current consumption capped at 450 mA and powered by 5 VDC, the C500-OA226 is efficient and reliable.

Power management is facilitated through its dual fuse setup, rated at 5 A and 250 V, with dimensions of 6.35 mm in diameter and 32 mm in length. This provides added protection against overload conditions. In terms of its switching characteristics, the C500-OA226 can handle a maximum switching capacity of 1.2 A at 250 VAC with a frequency range of 50/60 Hz. The module allows for a minimum switching capacity of 100 mA at 10 VAC and scales down to 10 mA at both 100 VAC and 240 VAC, thereby offering great flexibility in operational capacities.

Performance metrics include a leakage current measured at a maximum of 1.5 mA when operating at 120 VAC, while this value increases to 3.0 mA at 240 VAC. The residual voltage levels are also noteworthy, establishing a maximum of 1.5 VAC for loads between 100 to 600 mA and maintaining a maximum of 5.0 VAC for lower loads. For operational timings, the ON response is robust, rated at a maximum of 1 ms, while the OFF response time is determined by half the load frequency plus an additional 1 ms.

Furthermore, this TRIAC output module is designed with 16 discrete points, structured as 8 points common across 2 circuits, which enhances its usability in various industrial applications.