ManufacturerOmron
Product TypeDC Digital Input Module
Product LineCJ1
Part NumberCJ1W-ID261
Weight1.00 lbs (0.45 kg)
Input Voltage Type24 VDC
Total Input Points64 Points
Input Configuration16 Points per Common, 4 Commons
Rated Voltage24 VDC Nominal
Voltage Range20.4 to 26.4 VDC
Input Impedance5.6 kΩ
Input Current4.1 mA at 24 VDC
ON Level19 VDC min, 3 mA min
OFF Level5 VDC max, 1 mA max
ON Delay0 to 32 ms Adjustable
OFF Delay0 to 32 ms Adjustable
Simultaneous ON50% per Common
Backplane Current Draw90 mA max

Omron's CJ1W-ID261 is a robust DC digital input module, providing essential functionality for industrial applications. Operating with a nominal rated voltage of 24 VDC, this module supports a total of 64 input points configured in groups of 16 per common across four distinct commons. It can manage an input current of 4.1 mA when supplied with 24 VDC, enhancing its compatibility with various sensors and devices.

The voltage range for this module operates between 20.4 and 26.4 VDC, ensuring reliable performance across a range of power supplies. The input impedance is specified at 5.6 kΩ, contributing to the effective detection of input signals. The ON and OFF levels are defined, with the ON condition requiring a minimum of 19 VDC and 3 mA, while the OFF state requires no more than 5 VDC and a maximum current draw of 1 mA.

Users can adjust the ON and OFF delay settings, with a maximum delay of 32 ms, allowing for customizable response times based on system needs. Notably, the module permits simultaneous ON conditions for up to 50% of the points per common, ensuring efficient utilization of resources. The maximum current draw from the backplane has been specified as 90 mA, which is essential for ensuring that power resources are correctly allocated during operation.