Free UPS Ground on All Orders!
+1 (919) 205-4392
Omron CP1 CP1E-E14DR-A

Product image is representative; revision or series may vary. Contact us to request a specific version.

CP1E-E14DR-A

|

The CP1E-E14DR-A from Omron is a programmable logic controller with a wide input and output configuration. This unit can manage 8 inputs at 24 VDC and 6 relay outputs, each rated for up to 2A.

Out of stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for CP1E-E14DR-A

ManufacturerOmron
Product LineCP1
Part NumberCP1E-E14DR-A
Weight0.63 lbs (0.28 kg)
Outputs6 x relay outputs
Storage Temperature-20 to 75°C
Power Supply100-240 VAC
Inputs8 x 24 VDC inputs
Current2A per output
Operating Humidity10-90% RH (non-condensing)
Program Capacity2K steps
Data Memory Capacity2K words
Inrush Current24 VDC, 30 A for 20 ms max for cold start at room temperature
Insulation Resistance20 MΩ min. (at 500 VDC)
Power Consumption15 VA/100 VAC max, 25 VA/240 VAC max
Operating Voltage Range85 to 264 VAC

The Omron CP1E-E14DR-A is a versatile programmable logic controller engineered for efficient automation. It supports 8 inputs configured for 24 VDC and can output 6 relay commands rated at 2A per output. Users can program this controller with a capacity of 2K steps, supporting complex operations and control sequences.

With a memory allocation of 2K words, data handling, and storage are optimized for various applications. This device's operational voltage range extends from 85 to 264 VAC, ensuring compatibility with standard industrial power supplies. Its power consumption peaks at 15 VA when operating at 100 VAC and can reach 25 VA at 240 VAC.

This controller's physical dimensions are 90 x 85 x 86 mm, making it a compact solution for environments where space is a constraint. Regarding environmental resilience, it can operate in humidity levels ranging from 10 to 90% RH, maintaining functionality without condensation. For extreme conditions, the storage temperature can vary between -20 and 75°C.

At initial startup, it can handle a significant inrush current of up to 30A for 20 milliseconds, accommodating various types of loads. Insulation resistance is rated at a minimum of 20 MΩ when tested at 500 VDC, contributing to the unit's reliability and durability in demanding applications.