The CP1E-E30DR-A is a capable controller from Omron's CP1 series, featuring extensive input and output options. It integrates 18 inputs rated for 24 VDC and supports 12 relay outputs with a maximum current rating of 2 Amperes per output.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Omron |
|---|---|
| Product Line | CP1 |
| Part Number | CP1E-E30DR-A |
| Weight | 0.56 lbs (0.26 kg) |
| Inputs | 18 x 24 VDC inputs |
| Outputs | 12 x relay outputs |
| Current | 2A per output |
| Power Supply | 100-240 VAC |
| Program Capacity | 2K steps |
| Data Memory Capacity | 2K words |
| Operating Temperature | 0 to 55°C |
| Storage Temperature | -20 to 75°C |
| Operating Voltage Range | 85 to 264 VAC |
| Inrush Current | 24 VDC, 30 A for 20 ms max for cold start at room temperature |
| Power Consumption | 15 VA/100 VAC max, 25 VA/240 VAC max |
Omron's CP1E-E30DR-A is a versatile control solution equipped for diverse automation tasks. It features 18 inputs providing 24 VDC compatibility, suitable for connecting various sensors or devices. This unit features 12 relay outputs, each handling a maximum current of 2 Amps, allowing for significant control over actuators, lights, or other electrical components.
The CP1E-E30DR-A operates within a 100 to 240 VAC voltage supply range, accommodating different electrical configurations. The controller is compact with dimensions measuring 90 mm wide, 85 mm high, and 130 mm deep, making it ideal for constrained spaces.
The memory and program capacities are adequate for many applications, with 2K programming steps and a 2K-word data memory capacity facilitating efficient program execution and data handling. In operation, this device can function in temperatures ranging from 0 to 55°C and maintain integrity in storage environments between -20°C and 75°C.
This controller is lightweight, weighing only 600 grams. It can tolerate an inrush current of 30 Amps for up to 20 milliseconds during power-up, making it adaptable to high-load scenarios upon start-up. The power consumption varies depending on the input voltage, rated at 15 VA at 100 VAC and 25 VA at 240 VAC.