Free UPS Ground on All Orders!
+1 (919) 205-4392
Omron R88D R88S-H306G

Product image is representative; revision or series may vary. Contact us to request a specific version.

R88S-H306G

|

The Omron R88S-H306G is an industrial power unit capable of efficiently converting electrical energy. It operates in a voltage input range from 170 to 253 VAC and delivers high performance in demanding environments.

Out of stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for R88S-H306G

ManufacturerOmron
Product TypeIndustrial Power Unit
Product LineR88D
Part NumberR88S-H306G
Weight2.19 lbs (0.99 kg)
Voltage Input Range170 to 253 VAC
Power Input3000 VA for three-phase
Current Input7 A under three-phase conditions
Voltage Output240 to 350 VDC
Current Output6 A with three-phase input
Power Factor0.6 when connected to three-phase
Regenerative Energy Capacity200 J
Average Power Regeneration20 W
Thermal Output55 W at 220 V
Peak Inrush Current110 A
Fuse CapacityRated at 10 A
Fault Signal Output CapabilityUp to 240 VAC - 3 A, or 24 VDC - 3 A
Capacitance Between Terminals1410 µF
Mass2.2 kg

The R88S-H306G from Omron is a specialized industrial power unit. It features a voltage input range of 170 to 253 VAC. Under three-phase conditions, this unit supports a significant power input of 3000 VA and requires a current input of 7 A. Output capabilities include a voltage range of 240 to 350 VDC, with an output current rating of 6 A.

A notable aspect of this unit is its power factor, rated at 0.6 when connected to three-phase power. The unit is also equipped to handle regenerative operations, with a regenerative energy capacity of 200 J and average power regeneration measured at 20 W. Thermal output is calculated at 55 W with a 220 V input.

The unit can experience a peak inrush current of 110 A during startup. To ensure safety and protection, it is fitted with a fuse rated at 10 A. The unit also features a fault signal output capability that supports up to 240 VAC at 3 A or 24 VDC at 3 A, providing essential feedback for system monitoring. Capacitance measured between terminals is rated at 1410 µF.

With a total mass of 2.2 kg, the R88S-H306G is engineered for resilience and efficiency in industrial settings, delivering reliable performance across a broad spectrum of applications.