Product image is representative; revision or series may vary. Contact us to request a specific version.
The AS-B809-016 discrete input module from Schneider Electric is designed for 230 VAC systems. This module features a total of 16 inputs divided into two groups of eight, capable of operating within a voltage range of 160 to 260 VAC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Discrete input module, 230 VAC |
| Product Line | 800 Series |
| Part Number | AS-B809-016 |
| Weight | 2.44 lbs (1.11 kg) |
| Total Channels | 16 inputs |
| Channel Grouping | 2 groups of 8 inputs |
| Operating Voltage Range | 160–260 VAC, 47–63 Hz |
| Continuous Voltage | Up to 260 VAC |
| Short-Term Voltage | 300 VAC (10 sec) |
| Surge Protection | 400 VAC (1 cycle) |
| Activation Voltage | 112–148 VAC |
| Deactivation Voltage | 0–90 VAC |
| Input Current | 8.5 mA at 230 VAC |
| Response Time (On) | ≤7 ms (typ. 5 ms) |
| Response Time (Off) | ≤18 ms (typ. 12 ms) |
| Rack Mount | 1 slot |
The Schneider Electric AS-B809-016 is a highly functional discrete input module tailored for use in 230 VAC applications. Featuring 16 individual input channels, this module is organized into two distinct groups of eight channels each, allowing for structured system integration. It supports a broad operating voltage range from 160 to 260 VAC and functions effectively within a frequency range of 47 to 63 Hz.
This module can handle continuous voltage levels up to 260 VAC while also tolerating short-term spikes of 300 VAC for durations of 10 seconds. For transient conditions, it includes surge protection rated for 400 VAC for a single cycle, which safeguards against voltage peaks. The operational parameters ensure activation takes place between 112 and 148 VAC, while deactivation is effective within a range from 0 to 90 VAC.
Utilizing an input current of 8.5 mA at 230 VAC, the AS-B809-016 ensures quick response times, with activation occurring within a typical timeframe of 5 ms and a maximum of 7 ms. Deactivation is slightly slower, typically around 12 ms, with a maximum allowable time of 18 ms. The module requires just one rack slot for mounting, making it convenient for various installations.