Product image is representative; revision or series may vary. Contact us to request a specific version.
The LV430671 model from Schneider Electric is a thermal-magnetic circuit breaker designed for reliable protection in various electrical systems. With a nominal current rating of 125 A at 40°C, it operates effectively within a maximum voltage of 690 V AC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Thermal-magnetic circuit breaker |
| Product Line | ComPact |
| Part Number | LV430671 |
| EAN | 3606480011566 |
| Weight | 4.00 lbs (1.81 kg) |
| Pole Configuration | 3-pole, trip-3 (3P, 3t) |
| Nominal Current Rating | 125 A @ 40 °C |
| Maximum Operating Voltage | 690 V AC (50/60 Hz) |
| Insulation Voltage Rating | 800 V AC |
| Impulse Voltage Endurance | 8 kV |
| Utilization Class | Category A |
| Ultimate Breaking Capacity (Icu) | 70 kA @ 415 V AC |
| Trip Unit Model | TM-D |
| Trip Mechanism | Thermal-magnetic |
| Long-time Pick-up Range | 0.7–1×In (fixed delay) |
| Short-time Pick-up Setting | Fixed at 1 250 A |
| Physical Dimensions (W × H × D) | 105 × 161 × 86 mm |
The Schneider Electric LV430671 belongs to the ComPact series and is categorized as a thermal-magnetic circuit breaker. It is configured with three poles (3P) and features a trip-3 setup for enhanced safety. This unit can handle a nominal current of 125 A at an ambient temperature of 40 °C. Its robust design permits operation at a maximum voltage of 690 V AC across 50 or 60 Hz frequencies.
The insulation voltage rating is 800 V AC, allowing it to be used in applications that require advanced electrical protection. With an impulse voltage endurance rated at 8 kV, this circuit breaker can effectively manage overvoltage conditions. Operating under utilization class A, the LV430671 is well-positioned for high-performance environments.
The ultimate breaking capacity (Icu) of this device is noted at 70 kA when operating at 415 V AC, ensuring it can interrupt fault currents effectively. The trip unit, specified as a TM-D model, utilizes a thermal-magnetic mechanism for reliable disconnecting operations. This unit features a long-time pick-up range fixed between 0.7 and 1 times In, providing a fixed delay for delayed tripping, while a short-time pick-up setting is fixed at 1,250 A.
Measuring 105 mm in width, 161 mm in height, and 86 mm in depth, the LV430671 has a compact form factor fitting various installation spaces, while ensuring dependable circuit protection.