Free UPS Ground on All Orders!
+1 (919) 205-4392
Schneider Electric Modicon ABE7S16E2F0

Product image is representative; revision or series may vary. Contact us to request a specific version.

ABE7S16E2F0

|

The ABE7S16E2F0 model from Schneider Electric is a solid-state input relay sub-base with a capacity of 16 channels. It operates at a rated supply voltage of 110/130 V AC for sensors and 24 V DC for the PLC end.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for ABE7S16E2F0

ManufacturerSchneider Electric
Product TypeSolid State Input Relay Sub-base
Product LineModicon
Part NumberABE7S16E2F0
EAN3389110546279
Weight0.50 lbs (0.23 kg)
Number of Channels16
Terminal Block TypeRemovable
Rated Operational Current<= 0.0083 A (AC)
Switching Frequency<= 25 Hz (50% duty cycle)
Rated Supply Voltage110/130 V AC (sensor end), 24 V DC (PLC end)
Rated Insulation Voltage2000 V
Protection TypeInternal 1 A Fuse (Fast Blow) at PLC end
Current State 1 Guaranteed>= 5 mA (sensor end)
Supply Voltage Limits19...30 V DC (PLC end)
Response Time<= 20 ms from state 0 to 1 and state 1 to 0
Mounting TypeClips on DIN Rail or Screws on Solid Plate
Voltage State 1 Guaranteed>= 79 V (sensor end)

In the automated control environment, the Schneider Electric ABE7S16E2F0 serves as an effective solid-state input relay sub-base. It manages up to 16 channels, facilitating multiple connections in a system. Designed with a rated supply voltage of 110/130 V AC on the sensor side and 24 V DC at the PLC side, this module supports a broad range of applications.

The operational current is limited to 0.0083 A (AC), ensuring low power consumption while maintaining functionality. The switching frequency is capped at 25 Hz, based on a 50% duty cycle, thus delivering reliable performance in moderate-speed applications.

This sub-base incorporates a removable terminal block for straightforward installation, allowing quick connections and replacements. The response time for state transitions is at a maximum of 20 milliseconds, which ensures efficient processing of signal changes. Protection against overcurrent conditions is provided by a fast-blow internal fuse rated at 1 A, safeguarding the PLC end from potential damage.

With a guaranteed minimum current state of 5 mA at the sensor end, as well as a voltage state requirement of at least 79 V, the ABE7S16E2F0 meets operational safety and reliability standards. The supply voltage limits for the PLC end fall within the range of 19 to 30 V DC, contributing to its functional versatility. It can be mounted either via clips on a DIN rail or through screws on a solid plate, offering flexibility for various installation scenarios. Weighing approximately 0.5 kg, this module is compact and can seamlessly integrate into diverse systems.